2U enclosure LEDs
97
Actions:
•
If the Ops panel Module Fault LED is on, check the module LEDs on the enclosure rear panel to narrow the
fault to a CRU, a connection, or both.
•
Check the event log for specific information regarding the fault, and follow any Recommended Actions.
•
If installing an IOM CRU:
Remove and reinstall the IOM per
Check the event log for errors.
•
If the CRU Fault LED is on, a fault condition is detected.
Restart this controller from the partner controller using the SMC or CLI.
If the restart does not resolve the fault, remove the IOM and reinsert it.
•
If the above actions do not resolve the fault, contact Lenovo for assistance.
Disk drive carrier module LEDs
Disk drive status is monitored by a green LED and an amber LED mounted on the front of each drive carrier
. The drive module LEDs are identified in the figure, and the LED behavior is
described in the table following the figure.
•
In normal operation the green LED will be on, and will flicker as the drive operates.
•
In normal operation the amber LED will be:
Off if there is no drive present.
Off as the drive operates.
On if there is a drive fault.