146 Technical specifications
A
Technical specifications
Enclosure dimensions
1-The 2U24 enclosure uses 2.5" SFF disks.
2-The 2U12 enclosure uses 3.5" LFF disks.
1-The 5U84 enclosure uses 3.5" LFF disks in the DDIC carrier. It can also use 2.5" SFF disks with 3.5" adapter in the DDIC.
Enclosure weights
1-Weights shown are nominal, and subject to variances.
2-Rail kits add between 2.8 kg (6.2 lb) and 3.4 kg (7.4 lb) to the aggregate enclosure weight.
Table 29 2U enclosure dimensions
Specification
Metric
units
Imperial
units
Overall enclosure height (2U)
87.9 mm
3.46 in
Width across mounting flange (located on front of chassis)
483 mm
19.01 in
Width across body of enclosure
443 mm
17.44 in
Depth from face of mounting flange to back of enclosure body
576.8 mm
22.71 in
Depth from face of mounting flange to rearmost enclosure extremity
602.9 mm
23.74 in
Depth from face of Ops panel to rearmost enclosure extremity
629.6 mm
24.79 in
Table 30 5U84 enclosure dimensions
Specification
Metric
units
Imperial
units
Overall enclosure height (5U)
222.3 mm
8.75 in
Width across mounting flange (located on front of chassis)
483 mm
19.01 in
Width across body of enclosure
444.5 mm
17.50 in
Depth from face of mounting flange to back of enclosure body
892.2 mm
35.12 in
Depth from face of mounting flange to rearmost enclosure extremity
974.7 mm
38.31 in
Depth from face of Ops panel to rearmost enclosure extremity
981 mm
38.63 in
Table 31 Enclosure weights
CRU/component
2U12
(kg/lb)
2U24 (kg/lb) 5U84 (kg/lb)
Storage enclosure (empty)
4.8/10.56
4.8/10.56
64/141
Disk drive carrier
0.9/1.98
0.3/0.66
0.8/1.8
Dummy disk drive carrier (air management sled)
0.05/0.11
0.05/0.11
—
Power Cooling Module (PCM)
3.5/7.7
3.5/7.7
—
Power Supply Unit (PSU)
—
—
2.7/6
Fan Cooling Module (FCM)
—
—
1.4/3
SBB controller module (maximum weight)
2.6/5.8
2.6/5.8
—
SBB expansion module
1.5/3.3
1.5/3.3
1.5/3.3
RBOD enclosure (fully populated with modules: maximum weight)
32/71
30/66
—
EBOD enclosure (fully populated with modules: maximum weight)
28/62
25/55
130/287