Connectors
Air deflector
1. Connect the power cable to the replacement backplane.
2. Slide the backplane into the card guides, making sure that any nearby wires or
cables are not trapped or pinched.
3. Press firmly until the backplane is fully seated and clicks into place.
4. Reconnect the backplane cables.
5. Install the cover (see “Installing the cover” on page 61).
6. Replace the hard disk drives.
7. Slide the server into the rack.
8. Connect the cables and power cords.
9. Turn on all attached devices and the server.
Removing the SAS/SATA controller (hot-swap models)
Alignment pins
SAS/SATA controller card
To remove the SAS/SATA controller from the system board, complete the following
steps:
Chapter 4. Removing and replacing server components
95
Содержание ThinkServer RS110
Страница 1: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Страница 2: ......
Страница 3: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Страница 8: ...vi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Страница 18: ...xvi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Страница 74: ...56 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Страница 238: ...220 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Страница 251: ......
Страница 252: ...Part Number 46U0856 Printed in USA 1P P N 46U0856 ...