Information only; no action is required.
•
FQXPMUP0103I: Start to update linux driver
Severity: Info
User Action:
Information only; no action is required.
•
FQXPMUP0104I: Start to update UEFI
Severity: Info
User Action:
Information only; no action is required.
•
FQXPMUP0105I: Start to update BMC
Severity: Info
User Action:
Information only; no action is required.
•
FQXPMUP0106I: Successful to update the firmware
Severity: Info
User Action:
Information only; no action is required.
•
FQXPMUP0201M: BMC communication failed: EMMC2USB mount failure. Failed to update the
firmware
Severity: Error
User Action:
1. Restart BMC via BMC setting under uEFI setup on LXPM left panel.
2. Perform AC reset if the error still exist.
Note:
When performing AC reset, after power off AC, wait several seconds before power on AC.
After AC power is restored, power on the host system.
3. Use other Lenovo tools to perform the update (ex. XClarity Administrator, XClarity Controller, or the
OneCLI utility).
4. If the error still occurs, contact service to support.
•
FQXPMUP0202M: Transfer the update package error. Failed to update the firmware
Severity: Error
User Action:
1. Ensure the update package is undamaged and retry the update.
2. Ensure proper connection to USB/network drive and retry the update.
3. Restart BMC via BMC setting under uEFI setup on LXPM left panel.
4. Perform AC reset if the error still exist.
Note:
When performing AC reset, after power off AC, wait several seconds before power on AC.
After AC power is restored, power on the host system.
.
XClarity Provisioning Manager events
161
Содержание 7Y51
Страница 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Страница 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Страница 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Страница 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Страница 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Страница 175: ......
Страница 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...