Complete the following steps:
1. Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system.
2. Check power supply LEDs:
a. If AC LED is not lit, check power cord and input voltage. once the problem still exist, then replace
the power supply.
b. If power supply model is no AC LED, then please power off the system then reseat PSU and
reboot system
c. If problem still exist, please send system event log to service for further investigation.
•
FQXSPPW0061M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps:
1. Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system.
2. Check power supply LEDs:
a. If AC LED is not lit, check power cord and input voltage. once the problem still exist, then replace
the power supply.
b. If power supply model is no AC LED, then please power off the system then reseat PSU and
reboot system
c. If problem still exist, please send system event log to service for further investigation.
•
FQXSPPW0063M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps:
1. If the specified sensor is Planar 3.3V or Planar 5V, contact service for further support.
2. If the specified sensor is Planar 12V, check XClarity Controller (XCC)event log for power-supply-
related issues and resolve those issues.
89
Содержание 7Y51
Страница 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Страница 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Страница 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Страница 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Страница 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Страница 175: ......
Страница 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...