User Action:
Make sure that the correct login ID and password are being used.
•
FQXSPSE4007I: Security: Userid: [arg1] using [arg2] had [arg3] login failures from an SSH client at
IP address [arg4].
This message is for the use case where a user has failed to log in to a Management Controller from SSH.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Remote Login
SNMP Trap ID: 30
CIM Prefix: IMM CIM ID: 0041
User Action:
Complete the following steps until the problem is solved:
1. Make sure that the correct login ID and password are being used.
2. Have the system administrator reset the login ID or password.
•
FQXSPSE4008I: SNMPv1 [arg1] set by user [arg2]: Name=[arg3], AccessType=[arg4], Address=
[arg5], .
A user changed the SNMP community string
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0075
User Action:
Information only; no action is required
•
FQXSPSE4009I: LDAP Server configuration set by user [arg1]: SelectionMethod=[arg2],
DomainName=[arg3], Server1=[arg4], Server2=[arg5], Server3=[arg6], Server4=[arg7].
A user changed the LDAP server configuration
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0076
User Action:
Information only; no action is required
•
FQXSPSE4010I: LDAP set by user [arg1]: RootDN=[arg2], UIDSearchAttribute=[arg3],
BindingMethod=[arg4], EnhancedRBS=[arg5], TargetName=[arg6], GroupFilter=[arg7],
GroupAttribute=[arg8], LoginAttribute=[arg9].
A user configured an LDAP Miscellaneous setting
Severity: Info
Serviceable: No
.
101
Содержание 7Y51
Страница 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Страница 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Страница 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Страница 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Страница 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Страница 175: ......
Страница 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...