Table 2. Events organized by severity (continued)
Event ID
Message String
Severity
FQXSPEM4005I
SNMP [arg1] disabled by user [arg2] .
Informational
FQXSPEM4006I
Alert Configuration Global Event Notification set by user [arg1]:
RetryLimit=[arg2], RetryInterval=[arg3], EntryInterval=[arg4].
Informational
FQXSPEM4007I
Alert Recipient Number [arg1] updated: Name=[arg2],
DeliveryMethod=[arg3], Address=[arg4], IncludeLog=[arg5], Enabled=
[arg6], EnabledAlerts=[arg7], AllowedFilters=[arg8].
Informational
FQXSPEM4008I
SNMP Traps enabled by user [arg1]: EnabledAlerts=[arg2],
AllowedFilters=[arg3] .
Informational
FQXSPEM4009I
The UEFI Definitions have been changed.
Informational
FQXSPEM4010I
UEFI Reported: [arg1].
Informational
FQXSPEM4011I
XCC failed to log previous event [arg1].
Informational
FQXSPEM4012I
User [arg1] made system [arg2] Encapsulation lite Mode.
Informational
FQXSPEM4013I
Battery error was detected by RAID controller. The battery unit needs
replacement.([arg1],[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4014I
The RAID controller has problem with the battery. Please contact
technical support to resolve this issue.([arg1],[arg2],[arg3],[arg4],
[arg5])
Informational
FQXSPEM4015I
The RAID controller detected unrecoverable error. The controller
needs replacement.([arg1],[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4016I
The RAID controller detected one or more problems. Please contact
technical support for additional assistance.([arg1],[arg2],[arg3],[arg4],
[arg5])
Informational
FQXSPEM4017I
The RAID controller detected one or more possible configuration
changes within the subsystem. Please check the drive LED status. If
necessary, contact technical support for additional assistance.([arg1],
[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4018I
Enclosure/Chassis issue detected with one or more units. Please
check the enclosure/chassis units to repair the problem.([arg1],[arg2],
[arg3],[arg4],[arg5])
Informational
FQXSPEM4019I
Connectivity issue detected with the enclosure/chassis. Please check
your cable configurations to repair the problem.([arg1],[arg2],[arg3],
[arg4],[arg5])
Informational
FQXSPEM4020I
Fan problem detected with the enclosure/chassis. Please check the
enclosure/chassis unit fan for correct operation.([arg1],[arg2],[arg3],
[arg4],[arg5])
Informational
FQXSPEM4022I
Enclosure/Chassis power supply has problem. Please check the
enclosure/chassis unit power supply for correct operation.([arg1],
[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4023I
One or more virtual drive are in abnormal status that may cause
unavailable virtual drive. Please check the event logs and if events are
targeted to the same disk then replace the drive. If necessary, contact
technical support for additional assistance.([arg1],[arg2],[arg3],[arg4],
[arg5])
Informational
9
Содержание 7Y51
Страница 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Страница 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Страница 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Страница 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Страница 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Страница 175: ......
Страница 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...