Страница 1: ...User Manual 2U EOS Server Expansion Optimized Server SKU OSS EOS 2U 41 www onestopsystems com ...

Страница 2: ... Set up Installation 17 2 1 Installation Procedures Overview 17 2 2 Remove Top Cover 18 2 3 Check Storage USB 3 0 Cables 19 2 4 Remove faceplate 20 2 5 Remove Drive Tray 20 2 6 Install Storage Drive 21 2 7 Connect Input and Output devices 22 2 8 Power ON the system 23 2 9 Configure BIOS 24 2 10 Install Operating System 27 3 OSS Target Card Installation 28 4 Attach OSS Expansion Unit 30 4 1 Connect...

Страница 3: ...One Stop Systems OSS EOS 2U 4I 3 11 Contacting Technical Support 43 12 Returning Merchandise to One Stop Systems 43 13 APPENDIX A Compliance 44 FCC 44 CE 44 ...

Страница 4: ...ion or to alert you to the potential for hardware damage or personal injury Disclaimer We have attempted to identify most situations that may pose a danger warning or caution condition in this manual However One Stop Systems does not claim to have covered all situations that might require the use of a Caution Warning or Danger indicator ...

Страница 5: ...a Computer Before taking covers off a computer perform the following steps Turn off the computer and any peripheral devices Disconnect the computer and peripheral power cords from their AC outlets or inlets in order to prevent electric shock or system board damage In addition take note of these safety guidelines when appropriate To help avoid possible damage to systems boards wait five seconds aft...

Страница 6: ...ures which can include wrist straps and smocks when servicing equipment You can also take the following steps to prevent damage from electrostatic discharge ESD When unpacking a static sensitive component from its shipping carton do not remove the component s anti static packaging material until you are ready to install the component in a computer Just before unwrapping the anti static packaging b...

Страница 7: ...ent Memory in memory mode Cascade Lake only Expansion Slots EOS configuration 4 x PCIe 3 0 x16 HH FL Double Width slots 2 x PCIe 3 0 x16 HH HL Single Width slots 1 x PCIe 3 0 x4 HH HL slot with x8 physical connector 1x PCIe3 0 x4 M 2 slot for 2280 and 22110 M Key modules NVMe configuration 2 x PCIe 3 0 x16 FH HL Single Width slots 2 x PCIe 3 0 x16 HH HL Single Width slots 1 x PCIe 3 0 x4 HH HL slo...

Страница 8: ...VAC max inrush current each module EPS 12V Output type with 22A at 5V 83A at 12V 0 5A at 12V 22A at 3 3V and 3A at 5V Standby Environment Operating 5 C to 35 C 41 F to 95 F at 0 to 915m 3 000ft altitude 5 to 90 non condensing relative humidity max dew point 21 C max rate of change 5 C hr Non Operating 20C to 60 C 40 F to 140 F 5 to 90 non condensing relative humidity max dew point 27 C max rate of...

Страница 9: ...One Stop Systems OSS EOS 2U 4I 9 1 2 Overview ...

Страница 10: ...One Stop Systems OSS EOS 2U 4I 10 ...

Страница 11: ...One Stop Systems OSS EOS 2U 4I 11 1 3 Motherboard Layout ...

Страница 12: ...One Stop Systems OSS EOS 2U 4I 12 1 4 Quick Reference ...

Страница 13: ...One Stop Systems OSS EOS 2U 4I 13 1 5 Quick Reference Table ...

Страница 14: ...One Stop Systems OSS EOS 2U 4I 14 ...

Страница 15: ...ics controller VGA support via ASPEED AST2600 BMC I O Devices Serial COM Port One serial port on the rear I O panel COM1 One front accessible serial port header COM2 SATA 3 0 Eight I SATA 3 0 ports at 6 Gb s I SATA0 3 I SATA4 7 Two Intel PCH powered S SATA 3 0 Ports with support for SuperDOM Disk on Module devices S SATA4 S SATA5 Video VGA Connections One VGA port on the rear I O panel VGA2 One VG...

Страница 16: ...he following steps Inventory the shipping carton contents for all of the required parts Gather all of the necessary tools required for installation Read this manual 1 8 Tools Required for Installation To complete the installation of the product you will need a Phillips head screwdriver and ESD wrist strap to prevent electrostatic discharge ...

Страница 17: ...r off at the power on off switch does not remove power to components High voltage is still present CAUTION Before touching anything inside the enclosure move to an ESD station and follow proper ESD procedures Failure to do so may result in electrostatic discharge damaging the computer or its components For more information see Protecting Against Electrostatic Discharge in the Preface 2 1 Installat...

Страница 18: ... EOS 2U 4I 18 2 2 Remove Top Cover Remove the screw located on each side of the panel see photo below Remove the screw located on the top end of the cover see photo below Lift the front top cover up and slowly slide it out ...

Страница 19: ...hind the unit using both hands push the cover and then lift it up 2 3 Check Storage USB 3 0 Cables Check the SlimSAS 8 Lane to OCulink 4 Lane x2 cables are rigidly attached to the ports on the motherboard Check the other end of the cable Oculink is connected to the storage carrier interface board see photos below ...

Страница 20: ...fully remove the front faceplate or the front bezel Hold the front face plate on the right side as shown from the photos below and gently pull it to detach 2 5 Remove Drive Tray Locate the locking tab slide it to the left to unlock Pull the drive tray out from the unit by pressing the release button The drive tray handle will extend ...

Страница 21: ...2U 4I 21 Grasp the handle and gently pull the drive tray out of the chassis 2 6 Install Storage Drive Remove the two screws A securing the dummy bracket B to the hard drive tray C Remove the dummy drive from the hard drive tray ...

Страница 22: ...the screws Insert the hard drive and drive carrier into its bay vertically keeping the carrier oriented so that the release button is on the top When the carrier reaches the rear of the bay the release handle will retract Using the thumb push against the upper part of the hard drive handle Push the hard drive into the hard drive bay as illustrated below until the hard drive clicks into the locked ...

Страница 23: ...mouse keyboard VGA and Ethernet cables 2 8 Power ON the system Connect power cables to the power supplies Press the front Power Button Orange LED will illuminate immediately upon powering ON the system Power Supply LEDs will come UP as solid green ...

Страница 24: ...p a Go to Boot tab select and hit Boot Mode Select from the list select Dual See Photo C b Save and reset see Photo B 3 Hit delete key during boot up a Go to Boot tab select and hit Boot Option from the list select the EUFI USB Key NAME OF YOUR BOOT UP device See Photo D This is the name of USB bootable thumb drive containing the OS image b Save and reset See Photo B 4 Computer will restart and bo...

Страница 25: ...One Stop Systems OSS EOS 2U 4I 25 Photo A1 Photo B ...

Страница 26: ...One Stop Systems OSS EOS 2U 4I 26 Photo C Photo D ...

Страница 27: ...ems OSS EOS 2U 4I 27 2 10 Install Operating System Load or install Operating System of your choice from the Bootable USB Once you have completed the OS installation shutdown the system and install the OSS Host card ...

Страница 28: ...it see How to Remove Top Cover section The PCIe host card is a half height x16 capable PCIe card mounted to a full height bracket as shown below For low profile case applications change the mounting bracket to the low profile bracket You can order a low profile bracket by contacting our Sales Support Replacing the High Profile Bracket with Low Profile Bracket is done by removing the screws that ho...

Страница 29: ...ith a mounting screw Electrostatic Discharge ESD Warning All PCI cards are susceptible to electrostatic discharge When moving PCI cards it is best to carry the cards in anti static packaging If you need to set a PCIe card down be sure to place it inside or on top of an anti static surface For more information see Protecting Against Electrostatic Discharge in the Preface ...

Страница 30: ...f Target and Host adapter cards i e OSS OSS PCIE HIB616 X16 4 1 Connect LINK Cables Plug in the cables i e SFF 8644 between host and target cards Connect the four x4 SFF 8644 cables to the target card installed in the expansion unit Connect the other end of the cables to the host card Cable diagram below shows how to connect all four SFF 8644 cables between Host and Target cards ...

Страница 31: ...s to the expansion unit The expansion unit will power UP instantly Other expansion units will require you to manually turn the power switch ON Connect power cable s to the computer Turn On the computer Upon powering UP the computer it will initialize a link between host and target ...

Страница 32: ...ve the mounting screw located across from the M 2 slot Step 2 Align the M 2 Key edge connector to the M 2 key edge socket on the board Step 3 Slowly insert the media at 30 degree position into the socket until it is fully seated The SSD will naturally stand at an angle when inserted this is normal See photos below Step 4 Secure the M 2 SSD using the mounting screw Press down and hold the M 2 SSD w...

Страница 33: ...it as a new storage device Some motherboards will automatically detect an M 2 SSD but when that does not happen you will need to manually go to the BIOS and set the settings that an M 2 device is connected 1 Power UP the computer during the boot up process press Delete to enter BIOS 2 Go to Advanced Tab select and hit NVME Firmware Source from the list select AMI Native Support ...

Страница 34: ...b a Click Boot Mode Select from the dropdown list select Dual b Click LEGACY to EFI Support from the dropdown list select Enabled c Click Boot Option 1 find and select the NAME of your Storage Device 4 Go to Save Exit tab click Save Changes and Reset ...

Страница 35: ... OSS EOS 2U 4I 35 5 How to Remove Power Supply Pressing and holding the lever towards your right and gently pull the handle to remove power supply module CAUTION Turn OFF the unit first before removing the power supply ...

Страница 36: ...e on how to dismount or detach the power supply housing This will allow you to have physical access to the CPU and memory modules 1 Remove the PSU modules 2 Remove the two mounting screws underneath the metal enclosure 3 Remove the two mounting screws on the back of the unit see photos below ...

Страница 37: ... Systems OSS EOS 2U 4I 37 4 Remove the three mounting screws located on the side of the unit see photo below 5 Remove the air baffle 6 Slowly raise the PSU housing and lay it flat on the top surface of the unit ...

Страница 38: ...One Stop Systems OSS EOS 2U 4I 38 7 How to Remove the Fan 1 Loosen up the screw 2 Grasp the fan on both sides 3 Lift the fan 4 Pull the fan away from mounting bracket ...

Страница 39: ...stall the Fan 1 Align the two metal tabs on top of the two notches 2 Align the two fan connectors 3 Slowly push the fan down 4 Check both tabs are fully seated 5 Tighten up the screw to secure the fan 6 Photo below shows the fan is seated properly ...

Страница 40: ...I 40 Make sure the fan is properly installed Use photos below as reference on how to check if the fan is installed and secured properly Verify the screw is tightened see photos below Verify the fan is fully seated see photos below ...

Страница 41: ... pad to enter the BIOS 2 Once in the BIOS navigate to the IPMI option with the arrow keys 3 Select the BMC Network Configuration and press Enter 4 Select Update IPMI LAN Configuration press Enter and select YES 5 Configure the Address Source for DHCP or Static a Note If you select static configure the IP address subnet mask and default gateway Those fields should go to zeros before you configure t...

Страница 42: ...Cancel From here you can find various configuration settings logs and server health reports Here we will just focus on some Server Health options Server Health Senor Reading This page displays system sensor information including readings and status of the hardware components Event Log Shows the hardware events of the system Power consumption This page displays Power consumption information includi...

Страница 43: ...required you must contact OSS Service Representative to obtain a Return Merchandise Authorization RMA number Put this number and your return address on the shipping label when you return the item s for service One Stop Systems will return any product that is not accompanied by an RMA number Please note that One Stop Systems WILL NOT accept COD packages so be sure to return the product freight and ...

Страница 44: ...Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the service personnel s authority to operate the equipment NOTE The assembler of a pe...

Страница 45: ...One Stop Systems OSS EOS 2U 4I 45 ...

Страница 46: ...One Stop Systems OSS EOS 2U 4I 46 ...