Table 1. Specifications (7X69 and 7X70) (continued)
• Slot 14 - 15: PCI Express 3.0 for 4U PCIe riser card with the following slots available
depending on the riser card installed in slot 13:
– ThinkSystem SR860 2x8 PCIe FH riser 3 provides:
– Slot 14: PCI Express 3.0 x8
– Slot 15: PCI Express 3.0 x8
Note:
– The PCIe riser card uses x16 mechanical connectors with x8 signals.
– The riser card supports HBA and network/RAID adapter with external
connection.
– ThinkSystem SR860 1x16 PCIe FH riser 3 provides:
– Slot 14: GPU
– Slot 15: Not available in the riser card
RAID adapter
(depending on model)
The following options with support for RAID levels 0, 1, and 10 are available for this
server:
• ThinkSystem RAID 530-8i PCIe 12 GB Adapter
• ThinkSystem RAID 730-8i 1 GB Cache PCIe 12 GB Adapter
• ThinkSystem RAID 730-8i 2 GB Cache PCIe 12 GB Adapter
• ThinkSystem RAID 930-8i 2 GB Flash PCIe 12 GB Adapter
• ThinkSystem RAID 930-16i 4 GB Flash PCIe 12 GB Adapter
• ThinkSystem RAID 930-8e 4 GB Flash PCIe 12 GB Adapter
Fans
• Six (60 mm x 38 mm) internal system fans (N+1 redundancy)
• Two (60 mm x 56 mm) 4U PCIe riser assembly fans (N+1 redundancy)
Integrated functions
• Lenovo XClarity Controller provides service processor control and monitoring
functions, video controller, and remote keyboard, video, mouse, and remote drive
capabilities.
• One system-management RJ-45 connector on the rear to connect to a systems-
management network. This connector is dedicated to the Lenovo XClarity Controller
functions and runs at 1 GB speed.
• Light-path diagnostics
• Four universal serial bus (USB) ports:
– Two on the front of the server
– One USB 2.0 with Lenovo XClarity Controller management
– One USB 2.0 or 3.0 (depending on the model)
– Two USB 3.0 on the rear of the server
• One serial port
Electrical input
This server comes with three types of power supply units:
• 750-watt platinum power supply
– input power 115V or 230V ac
• 1100-watt platinum power supply
– input power 115V or 230V ac
• 1600-watt platinum power supply
– input power 230V ac
• 2000-watt platinum power supply
– input power 230V ac
Two power supplies provide N+1 redundancy support.
CAUTION:
240V dc input (input range: 180-300V dc) is supported in China ONLY. Power
supply with 240V dc input cannot support hot plugging power cord function.
Before removing the power supply with dc input, turn off server or disconnect dc
power sources at the breaker panel or by turning off the power source. Then,
remove the power cord.
6
ThinkSystem SR860 Setup Guide
Содержание 7X69
Страница 1: ...ThinkSystem SR860 Setup Guide Machine Type 7X69 and 7X70 ...
Страница 8: ...vi ThinkSystem SR860 Setup Guide ...
Страница 62: ...54 ThinkSystem SR860 Setup Guide ...
Страница 69: ...Chapter 3 Server hardware setup 61 ...
Страница 82: ...74 ThinkSystem SR860 Setup Guide ...
Страница 108: ...100 ThinkSystem SR860 Setup Guide ...
Страница 162: ...154 ThinkSystem SR860 Setup Guide ...
Страница 166: ...158 ThinkSystem SR860 Setup Guide ...
Страница 170: ...video connector front 15 rear 21 23 W working inside the server power on 57 162 ThinkSystem SR860 Setup Guide ...
Страница 171: ......
Страница 172: ...Part Number SP47A30799 Printed in China 1P P N SP47A30799 1PSP47A30799 ...