1. Read the safety information and installation guidelines (see
).
2. Turn off the server and peripheral devices and disconnect the power cords and all external cables (see
“Power off the server” on page 132
3. If the server is installed in a rack, remove the server from the rack.
4. Remove the top cover (see
“Remove the top cover” on page 89
).
5. Remove the PCIe expansion tray (see
“Remove the PCIe expansion tray” on page 92
).
To remove the system board air baffle, complete the following steps:
Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/watch?v=pIb0bIyfkDY&=
PLYV5R7hVcs-Ak9fT8QAx8fLbEivizjRtp
Step 1. Slightly slide power supply 2 out from the power supply bay (see “Remove a hot-swap power
supply unit” in
ThinkSystem SR860 Maintenance Manual
).
Step 2. Lift the power interposer from the server, and set it aside.
Figure 57. Power interposer removal
Step 3. Lift the system board air baffle from the server, and set it aside.
Attention:
Air baffle is required for airflow that creates proper cooling. Make sure proper air baffle
(s) for system configuration is installed before the power is turned on.
.
95
Содержание 7X69
Страница 1: ...ThinkSystem SR860 Setup Guide Machine Type 7X69 and 7X70 ...
Страница 8: ...vi ThinkSystem SR860 Setup Guide ...
Страница 62: ...54 ThinkSystem SR860 Setup Guide ...
Страница 69: ...Chapter 3 Server hardware setup 61 ...
Страница 82: ...74 ThinkSystem SR860 Setup Guide ...
Страница 108: ...100 ThinkSystem SR860 Setup Guide ...
Страница 162: ...154 ThinkSystem SR860 Setup Guide ...
Страница 166: ...158 ThinkSystem SR860 Setup Guide ...
Страница 170: ...video connector front 15 rear 21 23 W working inside the server power on 57 162 ThinkSystem SR860 Setup Guide ...
Страница 171: ......
Страница 172: ...Part Number SP47A30799 Printed in China 1P P N SP47A30799 1PSP47A30799 ...