Shipping and Packing List

Assembled 

PureAir S

 air purification system which includes:

• 

Cabinet (1)

• 

UVA Lampholder / PCO cartridge (secure to interior 

of cabinet) (1)

• 

UVA lamp in box (secure to interior of cabinet) (1)

•  Healthy Climate

®

 Carbon Clean 16

®

 Filter (located in 

interior of cabinet) (1)

• 

UVA lamp socket with 4-pin male connector assembly 

attached to light ballast electrical connector (1)

• 

Lennox Communication Control interface.

• 

Literature bag includes power cord (120VAC)

1

, instal

-

lation instruction, UVA Lamp Socket brass finger nuts 

(2), UVA Lampholder / PCO cartridge wing nuts (2) 

and warranty.

1

230VAC  power  cord  available  separately  (part  number 

91X44). 

Check equipment for shipping damage. If damage is found, 

immediately contact last carrier.

Models

Table 1. 

Unit Catalog Numbers

Model

Catalog Number

PCO3S-14-16

Y8905

PCO3S-16-16

Y8904

PCO3S-20-16

Y8903

Application

The 

PureAir

 S

 air purification system uses photocatalytic 

oxidation  (PCO)  technology  to  reduce  levels  of  airborne 

volatile organic compounds, cooking odors, common 

household odors, airborne dust particles, mold spores and 

pollen.  Each  unit  may  be  connected  to  either  120VAC  or 

230VAC power supply.
Lab tests confirm a 50% reduction in total volatile organic 

compounds  (TVOC)  within  the  first  24  hours  of  initial 

operation of the 

PureAir

 S

 air purification system. It may 

take up to 48 hours after initial system start-up to reduce 

the airborne chemicals that have built up in a home over a 

long period of time.
For peak performance, unit should be installed in homes 

with  TVOC  levels  that  are  less  than  1000  micro-gram  / 

cubic meter. Home source removal and ventilation may be 

required to lower total volatile organic compounds to this 

level.
The Healthy Climate

®

  Carbon  Clean  16

®

 Filter combines 

industry-leading MERV 16 filtration and carbon-coated fiber 

matrix.
For full feature benefits, the PureAir 

S

 must be used with 

an S30 Ultra Smart Thermostat and communicating indoor 

unit. 

The  iComfort  S30  Ultra  Smart  Thermostat  will  require 

firmware version 3.4 or higher to take advantage of all of 

the PureAir 

S

 features. 

New features included are:

• 

4-wire  connection  to  Lennox  communicating  indoor 

unit control

• 

Using sensors to:

 

>

Automatically detect dirty air filter

 

>

Display air filter life percentage

 

>

Monitor UVA lamp operational state (On or Off).

 

> Display UVA lamp life percentage

 IMPORTANT

Oil on metal ducts may cause odors.

Use a mild soap and water solution to remove oils from 

transitions and duct surfaces prior to installation.

 IMPORTANT

Do not use any form of silicone sealant.

Use  of  silicone-based  products  will  reduce  the 

effectiveness of, or damage the titanium dioxide coatings 

on the PCO cartridge.

 IMPORTANT

Route power cord away from traffic areas where the cord 

may become a safety hazard.

 IMPORTANT

UVA lamp life is shortened when lamp is turned off and on. 

Power to unit must remain on at all times.
Do not interlock lamp operation with air handler blower 

operation.

 CAUTION

Ultraviolet (UVA) radiation risk.
Prolonged exposure may cause skin or eye damage.
Avoid prolonged (weeks) exposure to skin or eyes.

 WARNING

Risk of carbon monoxide poisoning.

Can cause injury or death.
Do not operate system unless access panel is in place 

and properly secured. Operation of this equipment without 

the access panel in place may cause exhaust fumes to be 

drawn into occupied spaces.

 CAUTION

Sharp edges hazard.
Sharp edges can cause injuries.
Use protective gloves when grasping equipment edges.

Содержание PureAir PCO3S-14-16

Страница 1: ...licensed professional HVAC installer or equivalent service agency or the gas supplier WARNING Electric shock hazard Can cause injury or death Disconnect all electrical power supplies before servicing...

Страница 2: ...ay be required to lower total volatile organic compounds to this level The Healthy Climate Carbon Clean 16 Filter combines industry leading MERV 16 filtration and carbon coated fiber matrix For full f...

Страница 3: ...Ballast Figure 1 Parts Identification Dimensions top for bottom 8 3 4 222 11 16 17 1 3 4 33 1 3 4 33 1 5 16 33 1 5 16 33 INLET AND OUTLET OPENING SAME SIZE A B C D 1 AIR FLOW Power Connection UVA Lamp...

Страница 4: ...t and the titanium dioxide PCO cartridge Packing material should be disposed of properly IMPORTANT Possible odor emissions Chemical reactions may cause temporary odors after initial start up or after...

Страница 5: ...5 ton Modified Return Air Opening RETURN DUCT SUPPLY DUCT DUCT TRANSIITON Field Furnished FURNACE OR AIR HANDLER PCO3S RETURN DUCT SUPPLY DUCT OPTIONAL RAB RETURN AIR BASE PCO3S RETURN DUCT SUPPLY DUC...

Страница 6: ...iate fasteners to secure cabinet to the return air side of the air handling unit 4 Use field provided sheet metal screws 1 25mm maximum length to fasten the return air duct to the other side of the ca...

Страница 7: ...d wing nuts 2 NOTE There is an arrow on the front of the component indicating the correct way to install it 3 Connect UVA lamp 4 pin male connector to ballast female 4 pin connector BALLAST FOUR PIN F...

Страница 8: ...tached to the C terminals Keep all communication wiring as far away from the house electrical wiring and large electrical appliances as possible Recommended minimal distance is 15 feet 5 meters Unused...

Страница 9: ...to indicate the reset was successful Control Manual Reset When pressing both the SW1 and SW2 switches at the same time for ten seconds will reset the control to factory default Control can also be re...

Страница 10: ...Advance equipment configurations notifications tests diagnostics installation reports and general information about the system Go to menu settings advanced settings view dealer control center dealer c...

Страница 11: ...date for filter Date last filter reset was accomplished This is for display purposes only and cannot be changed Purifier life Provides percentage of remaining purifier life This is for display purpos...

Страница 12: ...n of the alert code press the down arrow to expand the description Service Urgent alerts are displayed on Home user screen under the homeowner and installer alert buttons Service Urgent means that a s...

Страница 13: ...ltage wiring transformer and equipment Check for incorrectly wired or loose or spliced connections between system components devices or units Make sure all unused wires are tied together and taken bac...

Страница 14: ...he thermostat Check the wiring connections between components Ohm wires Cycle power Any component that is miss wired may cause a false component code to be shown on system component Disconnect all wir...

Страница 15: ...Service Soon PA UV Lamp Off The light is determined to be off when the last three last light intensities measurements are below the set threshold Light is determined on after 1 set of five samples ar...

Страница 16: ...holder PCO cartridge and UVA lamp require annual replacement More frequent filter replacement may be required in applications with heavier dust or dirt loads or if you notice a reduction in odor remov...

Страница 17: ...e out the hinged control panel 6 Disconnect UVA lamp electrical connector from ballast 7 Remove both fasteners securing the UVA Lampholder PCO cartridge from the chassis 8 Slide out the UVA Lampholder...

Страница 18: ...to the PCO cabinet NO Repair Issues Is the lamp on Check ballast voltages see table below on red and blue wires at 4 pin connector Replace any burned out or damaged components NO Is the lamp on NO Con...