8. TROUBLE SHOOTING / ERROR HANDLING
Most problems can be checked and solved with help of the following chart. If the problem remains after consul-
ting this chart in details, please get in touch with your local dealer or contact the info line of your country.
8.1 Telephone connection / Telephone communication
Symptoms
Cause and /or remedy
LED is not lit after switching ON
Replace battery
Announcement „programming
deactivated: PIN“ by an attempt of
reprogramming
Programming function is locked => to be unlocked according to
section 5.4.2
Announcement „Beep Beep Beep“
Announcement „battery error”
Mains loss and low battery at the same time!
Battery is low => replace battery
Announcement „power failure”
Power failure, transformer not connected
Announcement „line check error “
No dial tones are audible during
test call
=> no tones are audible during the
dialling procedure
No dial tone has been detected:
Unit is not connected with the telephone network
Telephone network failure
Another telephone working on the same phone line is occupying
the line already
Plug in telephone cord
Check the telephone cord
Start
test-call
with different telephone
Test call does not call selected calling
number:
Announcement „calling number
n
error“
Calling number
n
is not programmed => Calling number 1 will
be dialled instead
Test call does not establish
phone
connection:
Announcement „calling
number
n
“ => dial tone audible
Calling number is wrong
Called party is not answering the phone
Remote access using dialling-in not
possible =>
is not
responding to the call
The dialling function is programmed for the two step modus (
section 0)
Remote access using dialling-in not
possible => disconnection after entering
of PIN-code
Wrong PIN-code entered => call again
does not react on
tone-
dialling commands
Current telephone does not support
or has
not been configured => for example pulse dialling
8.2 Acoustical monitoring
Symptom
Cause and /or remedy
Noise is not triggering an alarm
Factory setting supports monitoring of acoustics only on pos. III
of selection switch. (programming can be altered
section 5.6)
The unit has been deactivated by DTMF 7 => LED
alternatively 4s on / 4s off
By switching on the unit or after triggering an alarm, the
acoustical monitoring is not active during the
waiting time
of 20
seconds (
section 6.4) => LED is lit constantly during the
waiting time
!
Depending on the position of the selection switch, an alarm is
triggered with a different delay. Every time the noise exceeds the
pre set level, the LED is on (
section 6.4.1)
8.3 Motion detector (wired sensor 1)
Symptom
Cause and / or remedy
LED is on during WALK TEST, but no
alarm is triggered
Active/inactive by switching on the unit or between two alarms
is not expired
Supervision has been temporarily deactivated (deactivation)
Supervision is deactivated at current position of the
selection
switch
(I/II/III) (
section 5.6)
Motion detection is programmed to
verify presence
(
section
9.10), an alarm is only triggered if
no motion
is detected over a
programmed time.
Test mode => check section 10.2.4