16
LED indication
Comment
Green
*)
Standby: all contact detectors in neutral position
Red
*)
State of alarm: at least one contact detector is state of alarm or announce immediately
Red
Programming operation
Red blink shortly
Received detector signal is transferred to alarm unit
*) Blink in cycles: a malfunction occurred
a.
At least one contact sensor had send low battery status => start functional test
b. The radio-supervision (status) of at least one sensor is missing. Due to this problem the concentrator
stops sending his status report, so after a while the alarm unit will announce “sensor error, zone
n
“
c.
Mains power loss on concentrator => Alarm unit announces “battery error, zone
n
”
5.6 Alarm criteria’s according to the position of the selection switch I/II/III
standard modern is programmed as:
Sensor-1- alarm contact (motion detector) monitoring in all positions of the
selection switch
(I/II/III)
Acoustical monitoring enabled on
selection switch
position III only.
acoustical monitoring sensitivity in different address it depend on the selection switch table list
as follow:
Pos.
Alarm condition
III
Highest sensitivity => alarm will be triggered if the noise level exceeds 2-3 times within a short period
II
Medium sensitivity
I
Low sensitivity => alarm will be triggered if the noise level exceeds several times within a long period
Motion detector and noise monitor positions of the selection switch. This setting can be changed as follows:
A) Add up the entire individual values according to following table that your needs => Total=
n
.
Value Explanation
1
Acoustical monitoring is disabled on position III
(high sensitivity)
2
Acoustical monitoring is disabled on position II
(medium sensitivity)
(=factory setting)
4
Acoustical monitoring is disabled on position I
(low sensitivity)
(=factory setting)
8
Wired sensor 1 monitoring is disabled on position III
16
Wired sensor 1 monitoring is disabled on position II
32
Wired sensor 1 monitoring is disabled on position I
Example:
Acoustical monitoring shall be disabled on position I+III and wired sensor on position II
=>
n
=1+ 4 + 16 = 21
Selection switch on I:
monitoring sensor-1
Selection switch on II: acoustical monitoring in medium sensitivity
Selection switch on III: monitoring sensor-1
B) In case you would like to have an entry-delay for the sensor-1-contact, add following values:
Value v
Explanation
0
Alarm due to sensor-1 without any delay (=factory setting)
64
Alarm due to sensor-1 is delayed (entry-delay according to section 9.3)
Example:
Alarm due to sensor-1 shall be delayed =>
v
= 64
C) Program the total value (
s
=
v
+
n
= 64 + 21 = 85) as follows:
1. Slide
function switch
to PROG
2. Enter
*
.
3. Enter
2
.
6
.
8
.
4
.
<n>
(Example:
2
.
6
.
8
.
4
.
8 5 )
4. Enter
#
.
5. Enter
2
.
6
.
8
.
4
.
<n>
to confirm
(Example:
2
.
6
.
8
.
4
.
8 5 )
6. Enter
#
.
Cor
rect programming => acknowledge beep
Incorrect programming => announcement „error“
7.
Slide
function switch
to OFF
Notes:
1. In case of incorrect programming, slide
function switch
to OFF and repeat step 1 to 7.
2.
Factory setting:
s
= 6
a.
The acoustical monitoring: is locked on positions I and II
b. Sensor-1 alarm contact: alarm trigger without delay on all the positions.