22
7. USEFUL NOTES
7.1 Tone-dialling command
If you want to use
to its full potential a tone-dialling telephone is necessary. Nowadays most of
the telephones in use are working on tone dialling, also called DTMF or in-band signalling. Older telephones
are using pulse dialling. In case there is no tone-dialling telephone available, the features shown in section 6.7.3
cannot be used
Note:
An acoustic coupler can be purchased in electronic shops.
7.2 User information
7.2.1 Signals (beeps)
A single beep tone is used as a confirmation.
Three beep: Mains power loss AND battery low at the same time!
7.2.2 Announcement audible in loudspeaker of EasyAlarm®
Announcement
Message / Cause
„Individual message“
First message in case of an alarm
Abort
Disconnection caused from the change of the position of the
selection switch
Alarm acknowledged
Disconnection by pressing key 0 or emergency button
Alarm due to fire zone
n
Alarm triggered by smoke sensor (sensor function 1) on
n
Alarm due to sensor
n
Alarm call due to wired sensor
n
Alarm due to technical detector
zone
n
Alarm due to technical detector on zone
n
Alarm due to zone
n
Alarm due to sensor (function 3..7) on zone
n
Battery error
Battery is low => battery test after power on (function switch from PROG to
ON)
Battery error, zone
n
Announce if a low battery of wireless sensor (zone
n
)
is detected
Notes:
If the zone
n
is a concentrator than one of the learned-in contact
sensors has a low battery status or there is a mains power loss at the
concentrator itself
If there is a mains power loss at the repeater, than the first repeated
zone would also announce low battery status.
Calling number
n
Calling number
n
(
n
= 1..9)
Calling number sequence
Calling number sequence
Detector malfunction, zone
n
Status report missing at zone
n
Emergency call activated
Emergency call, initiated by emergency button
Emergency call deactivated,
alarm acknowledged
Emergency call confirmed
Error
Incorrect programming => the old value remains stored
Line check error
Telephone line check after power on was negative => dial tone missing
Output activated
Output switch activated
PIN
Request to enter PIN-Codes by locked programme
Power failure
Mains power missing => Mains power is tested after switching on the unit
Programming deactivated: PIN Request to enter PIN-Code to unlock programming
Supervision (I/II/III) <due to
noise/sensor
n>
activated
Announcement of the monitored alarm functions at current position of the
selection switch
(I/II/III) triggered by pressing key
5
.
during the
inactive
waiting period
(
section 6.3.1)
Supervision (I/II/III) activated Announcement in active supervision mode at current position of the
selection
switch
(I/II/III)
Supervision (I/II/III)
deactivated
Announcement deactivated supervision mode at current position of the
selection switch
(I/II/III)
Supervision due to sensor
activated
Presence verification activated (wired sensor 1)
to modify press *, to stop press
#
Recording of
individual message
Unacknowledged alarms:
n
Quantity of unacknowledged alarms
Zone x, y, z, is open
The monitor zone stay in active supervision open