Preparation procedure for programming:
If the detector is not open, open it by sliding a slotted screwdriver next to the LED between
upper and lower shell, twist it and thus lifting the upper shell up..
The two kinds of triggering of these detectors:
Is the detector set off, it transmits to the reception, which trigger an alarm immediately and
start calling the first alarm number. This kinds of the detector is called the immediate
detector (e.g. glass breakage detector or window contact (external), no entrance area)
If the detector is triggered, it transmits to the reception, which first waits for a certain time
(latency = 30 sec), in which you can deactivate the monitoring of the reception or switch to
part set (position I). This kind of detector is called Entry/ Exit (e.g. contact of main door)
Learn-in procedure:
Close upper shell of the contact => LED illuminates after a few seconds,
If not, open upper shell again, wait 3 seconds and close upper shell.
Sensor functions:
Technical, 24h, intern, Entry/ Exit, extern, remote lock (with status
report every 65 minutes), ON/OFF
Important note:
If the tamper contact of a remote lock is detected the appropriated zone will automatically deleted.
Therefore you have to check, that the alarm-unit is switched off, if you want to change the battery.
5.5.6.8 Concentrator for contact sensors
The concentrator combines up to ten wireless contact sensors to a single alarm zone (e.g. instantaneous
perimeter protection => type: extern). The zone will be reported as closed if all contacts are in the neutral
position (LED green). If a contact is in alarm position the entire zone is deemed to be open (LED yellow). The
status control (battery/supervision) of the detectors will also be concentrated, which means notification of a
dysfunction occurs as soon as one detector is defective.
Up to 10 contacts
concentrator
alarm unit
combines to a single zone
)
)
)
)
)
)
)
)
LED
Learn-in contact sensors:
Button
1. Press button on front of the box until the LED colour changes into red (about 5 second)
Confirmed with one beep
2. According to emitter instruction guide, program within 2 minutes
One dual tone as soon as the transmitter is recognized => LED change into green (stand by)
Two dual tones as soon as the transmitter is recognized and a prior programmed entry get
overwritten. *)
=> LED change into green (stand by)
3 beeps means no transmitter recognized within timeout => LED change into green (stand by)
3. Repeat step 1. and 2. for all contacts ( max. memory 10 sensors)
Notes:
*) If you try to learn-in more than 10 contacts, the “oldest” one will be replaced (first in -> first out)
Delete all contact zones (factory reset)
1. Press the button on front of unit until LED turns red (about 5 sec)
Confirmed with one beep
2. Continue pressing button until LED changes to green (about 5sec)
Cyclic dual tone confirms factory reset
Learn-in concentrator into alarm unit / functional test:
1. Prepare alarm unit for programming of zones according to section 4.2
Possible sensor function: 24h / intern / entry/exit / extern (with radio supervision every 65min)
2. Press button on front of the box briefly
Confirmed with one beep => concentrator sends its address code (LED blinks red briefly)
3. Within two minutes programmed detectors are signal as follow:
One beep for every register emitter (up to 8 beeps by very good reception)