7.4 Battery check / replacement
7.4.1 Alarm unit
If you hear „Battery error“ or three beep after switching on the battery should be replaced immediately as
follows:
1. Slide
function switch
to OFF
2. Disconnect
from the
telephone network, by removing the telephone cord
3. Open battery compartment and remove old battery
4. Insert new battery and close battery compartment
5. Reconnect telephone cord to
Notes:
Always use fresh 9V-batteries
Dispose the old battery properly
7.4.2 Sensor
If you hear the announcement „Battery error, zone
n
“ the battery of the appropriated wireless component
should be replaced immediately as follows. Pay attention to the note here that is special indication for sensor in
question.
Important notes:
If the battery of the telecommand key switch or remote lock is low, please put function switch of the
alarm unit to off, before you try to replace the battery. Otherwise a detected tamper would delete the
zone and you have to do the learning-in again
The announce for low battery on a zone can be because a mains power loss of the repeater or
concentrator => section 5.5.6.1 and
Fehler! Verweisquelle konnte nicht gefunden werden.
7.5 Maintenance
Slide
function switch
to OFF and remove telephone cord. Clean
if necessary using a moistened
cloth and dry it afterwards.
Note:
Do not use cleaning agents or solvent
Содержание EA-8-WRL868