18
6.4 Supervision mode
6.4.1 LED indication
In
active supervision mode
, the LED is flashing every 4 seconds. The LED is also lit, if the acoustical
monitoring is activated and the selected noise level is reached.
LED: acoustical monitoring inactive
LED: acoustical monitoring activated
LED: inactive mode
6.5 Alarm release
6.5.1 ..independent from state of arming (armed / disarmed)
Active by
Factory set
alarm cause
1)
I
II
III
Entry delay
Alarm
connection
Announce the alarm cause
Panic
Instantaneously
Listening-in
“Emergency call activated”
Emergency
2)
Delayed
Hands-free
“Emergency call activated”
Smoke
Delayed
Hands free
“Alarm due to fire zone
n
”
Technical detect.
Delayed
Hands free
“Alarm due to technical detector, zone
n”
24h
Instantaneously
Listening-in
“Alarm due to zone
n”
1. Factory setting cause of alarm (user specific changes not mentioned)
2. An emergency call will be triggered, if the button has been activated for one second. After a pre alarm
period of 20 seconds the text “emergency call activated” is announced. A pre warning announcement is
used to avoid false alarms (i.e. technical error like power failure, unwanted emergency calls). During the
pre warning period the alarm can be cancelled by pressing the emergency button respectively by pressing
key
0
.
or telecommand (arm/disarm)
6.5.2 ..if system is armed only
Active by
Factory set
alarm cause
1)
I
II
III
Entry delay
Alarm
connection
Announce the alarm cause
Intern
Instantaneously
Listening-in
Entry/Exit
Delay
Listening-in
Extern
Instantaneously
Listening-in
“Alarm due to zone
n”
Noise
Instantaneously
Listening-in
“Alarm due to noise
”
Sensor 1
2)
Instantaneously
Listening-in
“Alarm due to sensor 1
”
Sensor 2
3)
Instantaneously
Listening-in
“Alarm due to sensor 2
”
Power failure
4)
Delay 1 min.
Hands-free
“Alarm due to power failure
”
1. Factory setting causes of alarm (user specific changes not mentioned)
2. Sensor 1 can also be used as a presence verification sensor (
section 6.5.5)
3. Sensor 2 can be enabled according to section 10.2.3.2
4.
monitors mains voltage and triggers an alarm if power loss is longer than 10 to 20 minutes
(time-out according to section 9.4). The mains power monitoring does not start if after power up the mains
power is not detected. In this case the message „power failure“ will be announced. After any mains power
detection
automatically start power monitoring.
6.5.2.1 New alarm release
After an alarm
remains inactive during a waiting period of two minutes. Only if at expiration of
this waiting period an alarm event (wired sensor or wireless contact) occurs again, a new alarm is released.
Note:
After an alarms through sensor-1/2 or a wireless contact the sensor MUST return to its rest condition before
a new alarm can be triggered.
6.5.3 ..due to status report check (wireless sensors 0..6)
Wireless sensors with sensor function 0..6 are sending their status (battery condition/alarm condition/tamper)
every 65 minutes. If this status report is missing for more than 10 hours (due to battery low, out of range …)
will proceed as follows:
System is disarmed:
Announcement “detector malfunction, zone
n
” every 10 minutes
System is armed:
1 minute before an alarm is triggered there is an announcement “alarm due
to detector malfunction, zone
n
”. After this period
dials the
alarm-number(s) and establishes a hands-free connection.
Noise
Nois
4 seconds
4 seconds
4 seconds
4 seconds