5.4 How to program PIN-Code
You can change remote access PIN-code as follows:
1. Slide
function switch
to PROG
2. Press
#
.
You can prevent the alarm unit from unintended programming by pressing
*
.
3. Enter desired PIN-code (4 to 7 digits!)
4. Press
#
.
5. Re-enter PIN-code for confirmation
6. Press
#
.
If PIN-code is re-entered correctly it will be announced. If you selected program locking the
additional message „programming inactive: PIN” will be announced. In case of an incorrect
programming the message announced „Error“ will not be stored => old PIN-code remains active.
7. Slide function switch to OFF
5.4.1 Lock program mode
If you initiated programming new PIN-Code with key
*
the program mode is locked unless you unlock by re-
entering PIN-code. This feature prevents from unintentional reprogramming during operation.
5.4.2 Unlock program mode
Having the programming blocked as described in section 5.4.1, you can unlock as follows:
1. Slide
function switch
to PROG
Message „Programming inactive: PIN“ will be announced
2. Enter PIN-code and press
#
.
By entering correct PIN-code you will hear a confirmation beep, otherwise message „Error“
3. Slide function switch to OFF
5.5 Programming of wireless sensors (zones)
You have to learn in all the wireless-sensor to let the alarm unit know, what sensors belongs to the system.
Each sensor has a unique address (one out of 16million codes). During the learn-in process the sensor transmits
a special signal to avoid false learn-in of another sensor (like a activated motion-sensor).
The alarm unit can handle up to 10 zones. The zone number (0..9) is used to identify the location of the sensor
in alarm. The order of the zone and the sensor function is individual for each alarm-system.
Notes:
A zone can handle only one sensor, but using a concentrator you can combine up to 10 magnet-contacts
(RWT 72) to one zone.
The sensor function can program in each zone individually.
5.5.1 Detector function (defining kinds of alarm and telephone connection)
Sensor function
Monitored
if
Alarm delay
Entry delay
Alarm
connection ..
Alarm announcement:
7
Panic
No
Listening-in
“Emergency call activated”
8
Emergency
Yes
Hands-free
“Emergency call activated”
1
Smoke
Yes
Hands-free
“Alarm due to fire, zone
n
”
2
Technical detect.
Yes
Hands-free
“Alarm due to technical detector, zone
n
”
3
24h
Armed and
disarmed
No
Listening-in
4
Intern
1)
No
Listening-in
5
Entry/Exit
2)
Yes
Listening-in
6
Extern
3)
Armed only
No
Listening-in
“Alarm due to zone
n
”
9
Telecommand
Arm / Disarm (RWT 42 or Key868)
0
Remote lock
Arm / Disarm incl. radio supervision (RWT 72)
#0
Delete zone
Delete a wireless zone
Internal detector:
1) Internal wireless sensors (like motion sensors) that
are not monitored
if the system is
part-set (selection-switch on pos. I). So you can walk through this areas if you are at home.
Entry/Exit detector: 2) Entry/Exit-sensors (f.e. door-contact on main-entrance-door) which trigger an alarm if
the system is not disarmed within the entry delay period (20 seconds).
External detector:
3) Wireless sensors that protect the outer skin of the house and protect the object even if
you are at home.