5.4 How to program PIN-Code

You can change remote access PIN-code as follows:
1. Slide

function switch

to PROG

2. Press

#

.

You can prevent the alarm unit from unintended programming by pressing

*

.

3. Enter desired PIN-code (4 to 7 digits!)
4. Press

#

.

5. Re-enter PIN-code for confirmation
6. Press

#

.

If PIN-code is re-entered correctly it will be announced. If you selected program locking the
additional message „programming inactive: PIN” will be announced. In case of an incorrect
programming the message announced „Error“ will not be stored => old PIN-code remains active.

7. Slide function switch to OFF

5.4.1 Lock program mode

If you initiated programming new PIN-Code with key

*

the program mode is locked unless you unlock by re-

entering PIN-code. This feature prevents from unintentional reprogramming during operation.

5.4.2 Unlock program mode

Having the programming blocked as described in section 5.4.1, you can unlock as follows:
1. Slide

function switch

to PROG

Message „Programming inactive: PIN“ will be announced

2. Enter PIN-code and press

#

.

By entering correct PIN-code you will hear a confirmation beep, otherwise message „Error“

3. Slide function switch to OFF

5.5 Programming of wireless sensors (zones)

You have to learn in all the wireless-sensor to let the alarm unit know, what sensors belongs to the system.
Each sensor has a unique address (one out of 16million codes). During the learn-in process the sensor transmits
a special signal to avoid false learn-in of another sensor (like a activated motion-sensor).
The alarm unit can handle up to 10 zones. The zone number (0..9) is used to identify the location of the sensor
in alarm. The order of the zone and the sensor function is individual for each alarm-system.
Notes:

A zone can handle only one sensor, but using a concentrator you can combine up to 10 magnet-contacts
(RWT 72) to one zone.

The sensor function can program in each zone individually.

5.5.1 Detector function (defining kinds of alarm and telephone connection)

Sensor function

Monitored

if

Alarm delay

Entry delay

Alarm

connection ..

Alarm announcement:

7

Panic

No

Listening-in

“Emergency call activated”

8

Emergency

Yes

Hands-free

“Emergency call activated”

1

Smoke

Yes

Hands-free

“Alarm due to fire, zone

n

2

Technical detect.

Yes

Hands-free

“Alarm due to technical detector, zone

n

3

24h

Armed and

disarmed

No

Listening-in

4

Intern

1)

No

Listening-in

5

Entry/Exit

2)

Yes

Listening-in

6

Extern

3)

Armed only

No

Listening-in

“Alarm due to zone

n

9

Telecommand

Arm / Disarm (RWT 42 or Key868)

0

Remote lock

Arm / Disarm incl. radio supervision (RWT 72)

#0

Delete zone

Delete a wireless zone

Internal detector:

1) Internal wireless sensors (like motion sensors) that

are not monitored

if the system is

part-set (selection-switch on pos. I). So you can walk through this areas if you are at home.

Entry/Exit detector: 2) Entry/Exit-sensors (f.e. door-contact on main-entrance-door) which trigger an alarm if

the system is not disarmed within the entry delay period (20 seconds).

External detector:

3) Wireless sensors that protect the outer skin of the house and protect the object even if
you are at home.

Содержание EA-8-WRL868

Страница 1: ...Motion detector Wireless sensors Magnet Repeater contact Concentrator Alarm Telecommand Key Emergency button LEITRONIC AG Swiss Security Systems HOME SECURITY Use instruction EasyAlarm HOME Motion det...

Страница 2: ...alling in check call 21 6 11 Answering an incoming call 21 7 Useful notes 22 7 1 Tone dialling command 22 7 2 User information 22 7 3 Functional checks 23 7 4 Battery check replacement 24 7 5 Maintena...

Страница 3: ...ensors alarm can be disabled easily EasyAlarm can be used as remote switch With the appropriate accessory for example a light or siren can be activated or deactivated during the phone connection o Sir...

Страница 4: ...disconnect 2 3 Wireless sensors 868 65MHz permit according to description of wireless sensors 2 4 Power supply A transformer according to the safety regulation EN60950 provides power supply or by 9V b...

Страница 5: ...er programming If function switch is on position ON pressing any key will start a test call Keys are marked with 1 2 3 4 5 6 7 8 9 0 in the following sections 4 Loudspeaker The integrated loudspeaker...

Страница 6: ...apter into one of the EXT ports of the alarm unit and plug AC adapter to main socket 230V Optional wired sensors Operation with motion detector BBT PIR RJ45 Detail section 10 1 Operation with alarm co...

Страница 7: ...92 RWT 33 RWT 72 CON 868 Location 0 1 2 3 4 5 6 7 8 9 Learn in radio sensor Details according to section 5 5 16 Slide function switch to PROG 17 Enter 18 Press 0 to 9 according to desired zone per zon...

Страница 8: ...safety reasons 5 1 1 Point ID Contact ID alarm protocol If the alarm should be transferred to a alarm organisation using the Point ID Contact ID protocol the alarm number has to be followed by key an...

Страница 9: ...alling of a new number starts without delay You can demand the difference alarm sequence in each selection switch I II III this typical of alarm sequence definite in section 9 9 5 3 How to select user...

Страница 10: ...id false learn in of another sensor like a activated motion sensor The alarm unit can handle up to 10 zones The zone number 0 9 is used to identify the location of the sensor in alarm The order of the...

Страница 11: ...ne n to modify press star 5 Press key 6 Slide function switch to OFF Important note If the tamper contact of a telecommand key switch or remote lock sensor function 9 and 0 is detected the appropriate...

Страница 12: ...Paying attention to mounting it onto a flat surface and that the sabotage contact on the back is pressed in put the shell back on Bolt the upper shell with the four special screws Learn in procedure...

Страница 13: ...llance takes place Preparation procedure for programming If not yet open open the detector with a screwdriver on the bottom and remove the upper from the lower shell Take the 3V lithium battery from i...

Страница 14: ...t ON Slow 500ms for operation with external magnets OFF Fast 10 ms for operation with shock sensors 7 Determinate HOLD Status of transmitter ON There will be a 2 5 min dead time between two transmissi...

Страница 15: ...D green If a contact is in alarm position the entire zone is deemed to be open LED yellow The status control battery supervision of the detectors will also be concentrated which means notification of...

Страница 16: ...llows A Add up the entire individual values according to following table that your needs Total n Value Explanation 1 Acoustical monitoring is disabled on position III high sensitivity 2 Acoustical mon...

Страница 17: ...of the contact open close after power up can be selected according to section 9 11 2 The default value is all contacts are open The state of any contact zone will than be auto synchronised after the...

Страница 18: ...Sensor 1 2 Instantaneously Listening in Alarm due to sensor 1 Sensor 2 3 Instantaneously Listening in Alarm due to sensor 2 Power failure 4 Delay 1 min Hands free Alarm due to power failure 1 Factory...

Страница 19: ...delayed due to following reasons An alarm sensor in the area of the entrance must be delayed to have enough time to switch off the supervision mode before EasyAlarm dials the first calling number A pr...

Страница 20: ...ands free connection you can increase volume by pressing local key or decrease by pressing locale key Level can be adjusted in fifteen steps 1dB each and remains stored 6 7 5 Acknowledge alarm Termina...

Страница 21: ...ep dialling in procedure is for security reasons to avoid detecting of the alarm unit coincidently by an unknown caller Direct dialling in as well as other number of ringing cycles can be selected sec...

Страница 22: ...low battery status or there is a mains power loss at the concentrator itself If there is a mains power loss at the repeater than the first repeated zone would also announce low battery status Calling...

Страница 23: ...an the first repeated zone would also announce low battery status Emergency call activated Emergency call initiated by emergency button Output activated deactivated Confirm through press DTMF 6 DTMF 4...

Страница 24: ...ated wireless component should be replaced immediately as follows Pay attention to the note here that is special indication for sensor in question Important notes If the battery of the telecommand key...

Страница 25: ...s not answering the phone Remote access using dialling in not possible EasyAlarm is not responding to the call The dialling function is programmed for the two step modus section 0 Remote access using...

Страница 26: ...although the sensor LED is on Sensor not learned in Sensor deactivated at current position of the selection switch Detector is not monitored if system is disarmed or during exit delay respectively Pre...

Страница 27: ...arm as long until an acknowledgement is received OFF ON PROG 9 7 1 3 5 3 Value OFF ON PROG Value Comment 0 EasyAlarm calls the alarm numbers within the calling number sequence just once 1 9 EasyAlarm...

Страница 28: ...g with cord with end sleeves 9 6 2 Wiring Switzerland with T T SW06 1 Plug adapter SW06 into wall plate 2 Connect FCC cord between alarm unit and adapter SW06 3 Plug downstream phone into T T Jack of...

Страница 29: ...ction This function is disabled factory setting but can be enabled as follows 9 8 1 Enabling of remote programming Remote programming can be read out or modified as follows OFF ON PROG 9 7 1 3 7 6 Val...

Страница 30: ...hannel experience interference during reception or the detector is on the boarder of reception area If a detector does not report its status within supervision time then EasyAlarm will trigger an alar...

Страница 31: ...due to sensor 1 sensor 1 activated 10 1 4 Deactivation If the motion detector is not plugged in EasyAlarm automatically deactivates the supervision of the motion detector 10 1 5 Specification Supply...

Страница 32: ...o GND Sensor 1 is a normally closed contact Let Sensor 2 input open Sensor 1 is a normally open contact Select the appropriate contact to fit the monitoring 10 2 2 2 Operation with up to three alarm c...

Страница 33: ...0 0 1 1 1 0 Unused Gong on Gong type 000 I II III 00 Gong 0 1 1 01 0 enabled 10 Individual message 1 disabled 11 Beep loud 5 Press key The new register bit 7 bit 0 will be announced 6 Slide function s...

Страница 34: ...Shift function switch to PROG 2 Enter sequence 9 3 1 7 6 1 Current register bit 7 bit 0 will be announced followed by to modify press to stop press 3 If you want to keep current value proceed with ste...

Страница 35: ...mains unacknowledged siren floodlight C Output is activated during phone connection by request siren floodlight 10 5DIN Adapter interface EA ACDC SWI RJ45 Primary voltage 230 VAC 50 Hz Secondary volta...

Страница 36: ...nsion 70 x 30 x 60 mm L x W x H Weight 102 g Cord length 3 m RJ45 11 3Warranty Dear customer Each EasyAlarm is manufactured and tested according to stringent quality rules If the unlikely case should...

Страница 37: ...on 3 4 5 6 9 10 11 17 18 19 20 21 23 25 28 29 32 34 35 40 hands free 5 7 8 18 19 20 21 23 29 40 volume 20 listening in 7 19 20 21 29 35 40 time out 20 21 Contact sensor 7 8 14 26 32 40 Cord 4 5 6 24 2...

Страница 38: ...7 18 22 23 25 26 30 31 32 33 34 35 40 function 7 10 11 15 17 18 19 22 23 26 function type 7 10 11 12 14 15 40 motion 3 10 17 23 wired 16 Siren 3 33 34 35 Supervision active mode 18 20 22 23 inactive m...

Страница 39: ...39...

Страница 40: ...upervision mode without acoustical monitoring Supervision mode with acoustical monitoring Supervision mode inactive During phone connection Alarm release independent from state of arming armed disarme...

Отзывы: