![Leightronix LabVault-SD Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/leightronix/labvault-sd/labvault-sd_installation-configuration-and-operation-manual_1873724031.webp)
LABvault-SD
Control Commands
Page 27
2018-06-08
FUNCTION
COMMAND
DETAILS
ASCII RESPONSE
(Password) Login
PASS <PASSWORD>
Specifies password after
“USER” command has
been completed.
• If successful: 230 User
Logged in, proceed
• If already logged in: 335
Already logged in
• If not preceded by
successful USER attempt:
332 USER account not
specified
• If invalid password or
user entered (user will
be required to re-execute
USER command): 507
Login attempt FAILED
Logout
LOGOFF
Logs off the user and ends
the session. Restores
default user guest rights.
336 Session reset, rights
reset to guest privileges
Show Prompt
PROMPTON
Turns on the
“LABVAULT>” prompt.
200 Command OK
Hide Prompt
PROMPTOFF
Turns off the
“LABVAULT>” prompt.
200 Command OK
Play
PLAYFILE <FILENAME>
FILENAME is full
filename/ext of file to
be played. Filename
is case insensitive. \
Internal\mpeg\ directory is
assumed.
Ex.: PLAYFILE BROOKS.
MPG
200 Command OK
Record
RECFILE <FILENAME>
Time/Date stamp will
be appended if same
filename is used for
multiple records. Do
not include “.mpg” file
extension at the end of
filename. \Internal\mpeg\
directory is assumed.
(Alphanumeric, ‘-’, ‘_’
allowed)
Ex.: RECFILE BROOKS
200 Command OK
Pause Play
PAUSE
Pauses channel if it is in
play, unpauses it if it is in
pause (toggle).
200 Command OK
Stop
STOP
Stops the current playback
or record function.
200 Command OK