Page 12
2018-06-08
LABvault-SD
Web Interface
ePRO-BUS Setting
Click the “System” button to display the “System Management” screen and then click the “ePRO-BUS” tab. Click the
“Enable” button to allow the LABvault-SD to receive PRO-BUS control commands over your Ethernet network from
a NEXUS, UltraNEXUS, or UltraNEXUS-SDI server. Clicking “Disable” will prevent the LABvault-SD from receiving
ePRO-BUS commands.
NOTE:
Any LABvault-SD and NEXUS series server using the ePRO-BUS feature must be assigned a static IP address
and made available for UDP on Port 2000.
“ePRO-BUS” Tab on “System Management” Web Interface Screen
Serial Port Setting
The serial port mode setting, accessed by clicking the “Serial Port” tab on the “System Management” screen, applies to
the bottom serial port on the back panel of the LABvault-SD chassis. “Host” mode allows the LABvault-SD to receive
serial control commands from supported, external devices connected to the bottom serial port. “Camera” mode is not
currently supported. Currently, the LABvault-SD is automatically configured in the “Host” mode.
“Serial Port” Tab on “System Management” Web Interface Screen