90
Adj.:
Three different point types and some combinations
of them can be selected:
Line-
,
Intermediate-
and
StakeOut
-points. All points belonging to the selec-
ted point-types are adjusted.
<CONT>
DNA-Dde 46
<RESET>
to reset the
FixPoints
and heights
H
to
their default values.
Fixpoint 1:
Default for
FixPoint 1
is the first point of the se-lec-
ted line. Any point of the line can be selected.
Fixpoint 2:
Default for
FixPoint 2
is the last point of the se-lec-
ted line. Any point of the line can be selected as
long as it is different from FixPoint 1.
H:
Defaults for
H
are the measured heights. Enter the
fixed heights here after selecting the FixPoint ID's.
Changing the PixPoint ID will reset H.
<CONT>
to calculate the misclosure and to view
the results. A message appears if the misclosure
exceeds the closure tolerance.