61
Backsight display
First enter all required values and then trigger the
measurement.
DNA-Dde 13
Entries:
PtBS
Point number for the starting point.
The standard value is "1".
Rem
Remarks to the measurements.
After the measurement:
H BS (height backsight), dH, Staf and Dist
are
displayed with corresponding vales.
<REC>
Save measurement and continue to foresight.
<LAST>
Data and measured values of the last foresight are
displayed.
<END>
Quits the "Meas & Rec" program. As long as no
new line is started, the current line can always be
continued.
Switching to intermediate sight or set out
sight
Switching is only possible from the foresight to cal-
culate the intermediate and setout sights. Requires
a valid backsight for the station.
Note that this is a significant difference to
line levelling-programs: Point-to-point and
stakeout points can only be called up after comple-
ting all measurements of a station i.e after measu-
ring the foresight.
MEAS & REC BF
PtBS:
1
Rem : ------
H BS: 251.0257 m
HCol: 254.1417 m
Staf: 3.1160 m
Dist: 16.56 m
<END> <LAST>
<REC>
QC
EC