55
Managing point IDs
Point IDs are handled differently if they are for line
points (foresight), intermediate or setout sights.
Line points (foresight)
The instrument will suggest a
running
automati-
cally incremented
number
as a foresight point ID.
The starting point ID and the increment are defined
in the function [FNC]/ "PtID & Increment"
.
Swit-
ching the instrument on, set PtID value to A1.
Manually entered foresight point IDs are taken as
individual numbers
and are only valid for single
measurements. The next foresight number will
automatically be a running point ID.
Intermediate points
(intermediate/ setout sight)
A special range of numbers are reserved for inter-
mediate and setout sights. When switching on the
instrument they begin at point ID 1001. A manually
entered point ID is always a
running number
and
is automatically incremented. Set increment in
[FNC].
Содержание DNA 10
Страница 1: ...Leica DNA03 DNA10 User Manual Version 2 0 English ...
Страница 125: ...125 File Displays the file for checking IMPORT Start data import NEWJOB Create new job ...
Страница 157: ...157 ...