148
Heating
on/off switch, sets in below -5°C
Dimensions
Instrument
Height (incl. hand grip)
168mm +/-5mm
Width
on the side drives
240mm
instrument body
206mm
Length
210mm
Container
468 x 254 x 355mm (L x B x H)
Weight
incl. battery GEB111
2.85kg
Measured values corrections
Collimation error correction
automatically
Earth curvature correction
on/off switch; level
probe with correction
Record
Internal storage
approx. 6000
measurements or about
1650 stations (BF)
Serial interface RS232 from "Measure & Record"
in GSI-8/16-format
Data backup
PCMCIA-card (flash,
SRAM),
up to 32MB capacity
Temperature range
Storage:
-40°C - +70°C
Operation
-20°C - +50°C
Environmental conditions
Water and dust-proof
IP53 (acc. IEC60529)
Humidity
up to 95% humidity no condensation
Magnetic field sensitivity
Line-of-sight difference in horizontal constant
magnetic field at a field strength of 0
μ
T up to
±400
μ
T [4 Gauss].
≤
1"
Battery powered
Batteries (NiMh)
GEB111
GEB121
Voltage
6V
6V
Capacity
1800mAh 3600mAh
Operating life DNA
12h
24h
Battery adapter GAD39 only for Alkaline batteries,
6 x LR6/AA/AM3, 1.5V
Содержание DNA 10
Страница 1: ...Leica DNA03 DNA10 User Manual Version 2 0 English ...
Страница 125: ...125 File Displays the file for checking IMPORT Start data import NEWJOB Create new job ...
Страница 157: ...157 ...