REMOTE CONTROL COMPONENT LAYOUT
9
In order to access:
a. Pilot Assembly (including thermocouple)
b. Controls
It will be necessary to dismantle the burner tray. Please use the following procedure.
1. Ensure the appliance has fully cooled down.
2. Isolate gas supply.
3. Remove all the ceramic components off the fire and carefully placed to one side.
4. Working from the front of the fire, remove the lower fixing bracket screws and the two screws at the rear of the tray.
5. Disconnect the 8mm gas supply pipe using a 15mm spanner. This should then enable the burner to be removed
from its housing.
Break-down for access to components
1. Working from the front of the fire remove the two upper fixing point screws.
2. Remove the two pilot assembly screws.
3. Working from the rear of the burner tray, remove the two silencer bracket screws.
4. Slide the silencer (white ceramic block) upwards which will then give you open access to the main gas injector.
5. Remove the locking nut and washer using a 14mm spanner.
6. Remove the burner tray from the controls to gain access to the connections on the rear of the control unit.
7. The control unit will slide forward off it’s retaining tab.
8. Re-assembly is the exact reversal of the above procedure.
Pilot assembly
Pressure test point
Lower fixing point
Upper fixing point
Battery cover panel
Controls
Heat shield
Fig. 8