Operator's Manual
Configure LabNotebook Preferences
To configure the behavior of the LabNotebook tool, on the menu bar, choose
File
→
Lab Notebook
, then
touch the
Preferences
tab.
Select/deselect the following options:
Prompt for Report Title Before Saving
opens the LabNotebook dialog when a new entry is created. You can
elect to name notebook entries using only the date/timestamp by leaving this box unchecked.
Annotate Report Before Saving
opens the Drawing Toolbar to annotate a notebook entry as soon as it is
created.
Save Report When Hardcopy Pressed
configures the Front Panel print button to create a new notebook
entry whenever it is pressed.
Use Print Colors
outputs waveforms on a white background. The
print colors
used for each trace are set
in
Utilities > Preferences Setup > Colors
. This option helps save ink/toner when printing reports.
Hardcopy Area
determines how much of the screen image is included in the report: grid area only, grid
area plus dialog, whole screen. Touch the field and choose from the pop-up menu.
Attach Setup & Waveforms
attaches these files for each trace in the report: waveform data (.trc), a screen
dump (.png), oscilloscope setup file (.lss), report template file (.xsl), and export record (.htm).
Optionally, touch the
Configure E-Mail
button to set the recipient address and server information on the
Preferences E-mail dialog.