B
–7
Enhanced Resolution
Cautionary Notes
Ø
The enhanced resolution function can only improve the resolution of a trace; it cannot
improve the accuracy or linearity of the original quantization by the eight-bit ADC.
Ø
The constraint of good temporal response excludes the use of maximally-flat filters.
The pass-band will therefore cause signal attenuation for signals near the cut-off
frequency. The highest frequencies passed may be slightly attenuated. The frequency
response of a typical enhanced resolution filter (the 2-bit enhancement filter) is
illustrated below, indicating the –3 dB cut-off frequency of 5.8% of the Nyquist
frequency.
Ø
The filtering must be performed on finite record lengths: data will lost at the start and
end of the waveform, so that the trace becomes slightly shorter after filtering.
Ø
The number of samples lost is exactly equal to the length of the impulse response of
the filter used, and thus varies between two and 117 samples. Owing to the
oscilloscope’s very long waveform memories, this loss — just 0.2% of a 50 000 point
trace — is not normally noticed. However, it is possible to demand filtering on a record
so short, there would be no data output, and in this case the scope will not allow
filtering.
Содержание 9300C Series
Страница 1: ...Operator s Manual LeCroy 9300C Series Digital Oscilloscopes Revision A January 1998 ...
Страница 8: ...1 3 billed for parts and labor related to the repair work and for shipping ...
Страница 18: ...4 1 4 Introduction to the Controls Two Channel Front Panel ...
Страница 19: ...4 2 Introduction to the Controls Four Channel Front Panel ...
Страница 92: ......
Страница 111: ...11 3 Dual Quad ...
Страница 112: ...11 4 Display Parameter s XY only ...
Страница 113: ...11 5 XY Single XY Dual ...
Страница 127: ...12 10 UTILITIES Protected will be displayed on the upper part of the grid whenever the medium is accessed for writing ...
Страница 138: ...12 21 Ø FLASH UPDATE Offering the Update from and Update Program menus illustrated next page ...
Страница 139: ...12 22 UTILITIES The full screen warning message shown when FLASH UPDATE has been selected ...
Страница 142: ...13 2 WAVEFORM STORE RECALL ...
Страница 182: ......
Страница 189: ...A 15 9344C Series 9350C Series 9354C Series 9354CTM 50 000x 9344CL 9350CL 9354CL 100 000x ...
Страница 200: ...A 26 Specifications FourChannelsCombined by PP094 Adapter Peak Detect OFF 4 GS s 400k 2M 8M One PP094 input ...
Страница 252: ...E 6 Appendix E ...
Страница 275: ...Index 9370C 9374C Series A 18 9384C Series A 24 Zoom menu 10 7 Zoom of Math Functions 10 1 ...