EM3E Series EtherCAT Stepper Drive User Manual
50
2007
00
Action
when
disabled
R/W/S
UINT
0-1
0
-
0:
Don't
respond
to
commands, and the motor
shaft is not locked;
1:
Don't
respond
to
commands, but the motor
shaft is locked;
2010
01
Internal filtering
time
R/W/S
UINT
0-32767
100
0.1ms
Internal smoothing time
for control command.
2012
00
Soft-starting
time
R/W/S
UINT
10-3000
1
ms
Internal smoothing time
for starting current.
2013
00
Auto-tuning
at
power on
R/W/S
UINT
0-2
1
--
1: Yes. 0: No
201A
01
Locking current
percentage
of
power on
R/W/S
UINT
0-100
100
%
Usually keep the default
value.
201B
00
Locking
duration time
R/W/S
UINT
0-1500
200
ms
Appropriately reduce this
value if you want to shorten
the time of locking shaft.
201C
00
Max
time
to
close brake
R/W/S
UINT
100-10000
1000
ms
Usually keep the default
value
201D
00
Zero speed point
R/W/S
UINT
0-500
10
0.1r/s
-
2047
00
Over
voltage
point
R/W/S
UINT
0-1000
75
V
2048
00
Bus-voltage
R
UINT
0-65535
-
V
-
2051
00
Motor running
direction
R/W
DINT
0-255
0
--
Valid when 0x225C= 0;
0: CCW direction
1 or 4: CW direction
2056
00
Alarm detection
selection
R/W/S
DINT
0~65535
65535
--
Bit setting:
=1: Yes; =0: No
Bit0: over-current ( Cannot
be changed)
Bit1: over-voltage
2090
01
Current loop Kp
R/W
DINT
0~32767
1500
--
--
02
Current loop Ki
R/W
DINT
0~32767
300
--
--
03
Current loop Kc
R/W
DINT
0~32767
300
--
--
2150
00
Slave ID
R/W/S
UINT
0-256
1
--
Valid when 0x2151= 1;
2151
00
Slave
ID
resource
R/W/S
UINT
0-10
0
--
0: DIP switches
1: Setting by 0x2150
2: ESC
2152
01
Input1 function
R/W/S
DINT
0-65535
0x17
(Decim
al 23)
--
Default is touch probe1,
take effect changes need
restart power
02
Input2 function
R/W/S
DINT
0-65535
0x18
(Decim
al 24)
--
Default is touch probe2,
take effect changes need
restart power
03
Input3 function
R/W/S
DINT
0-65535
0x16
(Decim
al 22)
--
Default is origin signal, take
effect changes need restart
power