EM3E Series EtherCAT Stepper Drive User Manual
38
Table 6.2: Objects Dictionary related to each operation mode
Operation
Modes
Index
+
Sub-index
Name
Data Type
Access
Unit
PDO
Configura
tion
SDO
Configu
ration
CSP Mode (8)
6040+00
Control Word
U16
RW
—
Must
-
607A+00
Target Position
I32
RW
P
Must
-
6041+00
Status Word
U16
RO
—
Must
-
6064+00
Actual Position
I32
RO
P
Must
-
606C+00
Actual Velocity
I32
RO
P /S
Can
Can
PP Mode (1)
607A+00
Target Position
I32
RW
P
Recomme
nd
Can
6081+00
Max
Profile
Velocity
U32
RW
P
Can
Can
PV Mode (3)
60FF+00
Target Velocity
I32
RW
P
Recomme
nd
Can
PP Mode (1)
And PV Mode
(3)
General
6040+00
Control Word
U16
RW
—
Recomme
nd
Can
6083+00
Profile
Acceleration
I32
RW
P/S
2
Can
Can
6084+00
Profile
Deceleration
U32
RW
P/S
2
Can
Can
Homing Mode
(6)
6040+00
Control Word
U16
RW
—
Recomme
nd
Can
6098+00
Homing Method
I8
RW
—
Can
Can
6099+01
Fast
Homing
Velocity
U32
RW
P /S
Can
Can
6099+02
Slow
Homing
Velocity
U32
RW
P /S
Can
Can
609A+00
Homing
Acceleration
U32
RW
P /S
2
Can
Can
607C+00
Homing Offset
U32
RW
P
Can
Can
PP,
PV
and
HOME
Mode General
6041+00
Status Word
U16
RO
—
Recomme
nd
Can
6064+00
Actual Position
I32
RO
P
Recomme
nd
Can
606C+00
Actual Velocity
I32
RO
P /S
Can
Can
All
operation
modes General
60B8+00
Touch
Probe
Control Word
U16
RW
—
Recomme
nd
Can
60B9+00
Touch
Probe
Status Word
U16
RO
—
Recomme
nd
Can
60BA+00
Touch Probe 1
Positive Value
I32
RO
P
Can
Can
60FD+00
Digital
Input
Status
U32
RO
—
Recomme
nd
Can
603F+00
Latest
Error
Code
U16
RO
P
Recomme
nd
Can
Other Related
6060+00
Operation Mode
I8
RW
—
Can
Can
60B0+00
Position Offset
I32
RW
—
Can
Can
6082+00
Start Velocity
U32
RW
P /S
Can
Can
6085+00
Quick
Stop
Deceleration
U32
RW
P/S
2
Can
Can
6061+00
Displayed
Operation Mode
I8
RO
—
Can
Can
No matter using which operation mode, it can not be separated from the reading and writing of
Control Word (6040h) and Status Word (6041h). Master and slave stations use these two