14. STATUS DISPLAY
167
14.5.2
Setting the Sample Number
To scroll through the data dump display samples, follow the procedure below.
If you press F•D 1, the sample number begins from EAV.
Procedure
STATUS
→
F•2 SDI ANALYSIS
→
F•1 DATA DUMP
→
F•D 1 SAMPLE SELECT
14.5.3
Setting the Line Number
To select a line number in the data dump, follow the procedure below.
If you press F•D 2, the selected line changes to the first video line.
Changing this setting will also change the picture, video-signal-waveform, and
vector-display line selection settings.
Procedure
STATUS
→
F•2 SDI ANALYSIS
→
F•1 DATA DUMP
→
F•D 2 LINE SELECT
14.5.4
Setting the Display Mode
To set the data dump display mode, follow the procedure below.
Procedure
STATUS
→
F•2 SDI ANALYSIS
→
F•1 DATA DUMP
→
F•1 MODE
Settings
RUN:
The input signal data is automatically updated and displayed (this is the
default value).
HOLD:
The input signal data is retained and displayed.
14.5.5
Selecting the Display Format
To select the data dump display format, follow the procedure below.
The types of display formats that you can select vary depending on the link format.
Procedure
STATUS
→
F•2 SDI ANALYSIS
→
F•1 DATA DUMP
→
F•2 DISPLAY
Settings (when the link format is set to single)
SERIAL:
The data is converted from parallel to serial data and displayed (this is the
default value).
COMPO:
The data is converted from parallel to serial data, split into Y, Cb, and Cr, and
then displayed.
Settings (when the link format is set to dual)
LINK A:
The parallel converted data sequences of link A are displayed (this is the
default value).
LINK B:
The parallel converted data sequences of link B are displayed.
LINK AB:
Links A and B are combined, and their parallel data sequences are displayed.