14. STATUS DISPLAY
159
14. STATUS
DISPLAY
14.1
Status Display Explanation
The status display appears when you press STATUS.
Generally, the numbers displayed here represent error counts.
Errors are counted by field. Only one error can be counted for a single field, no matter how
many errors occur on that field. The maximum error count is 999999. Once a count of 999999
is reached, the display will continue to show 999999 even if more errors occur.
Errors are not displayed for items whose F•5 ERROR CONFIG setting is set to OFF.
Figure 14-1 Status display
• Signal
Whether or not an SDI signal is being received through one of the SDI input connectors is
indicated here.
When SDI signal input has been detected, “DETECT” appears. Otherwise, “NO SIGNAL”
appears.
“NO SIGNAL” may appear even when a signal is received through a connector if the signal
amplitude is small or if there is a lot of jitter. If “NO SIGNAL” appears, the rest of the
information listed below will be blank.
• Format
The input signal format is indicated here.
“-----” appears when the input signal format is not supported by the LV 7380 or when it
differs from the format specified in the unit setup. When this happens, the rest of the
information listed below will be blank.
• CRC Ych, CRC Cch (When an HD signal is being applied)
An error is counted when the CRC embedded in the input signal is different from the CRC
that the LV 7380 calculates. Errors are counted separately for the luminance signal (Ych)
and the chrominance signal (Cch).