12. PICTURE DISPLAY
135
• Loading a User-Defined Correction Table into the LV 7380
You can load up to five user-defined correction tables into the LV 7380.
To load a user-defined correction table into the LV 7380, follow the procedure below.
1. Create a user-defined correction table.
Example (TEST.CLT):
#################################
NAME:SAMPLE_1
TYPE:0
#Input -7% 0
# 109%
4095
#Output 0%
0
# 1000%
65535
#Input Output
#################################
0 0
1 16
2 32
(Omitted)
4093 65488
4094 65504
4095 65520
# EOF
Comment
Keyword
Keyword
Comment
Comment
Comment
Comment
Comment
Comment
Data
Data
Data
Data
Data
Data
Comment
When you create a correction table, make sure that it conforms to the specifications
listed below.
Overall File Specifications
File Type
ASCII text file
Extension .CLT
End-of-Line Character
CR+LF
Number of Lines
5000 or less
Number of Characters per Line 255 or less (including CR+LF)
File Name Length
20 characters or less (excluding the extension)
Permitted File Name Characters Letters of the alphabet (A to Z; uppercase and
lowercase), numerals (0 to 9), and underscores (_).
Comment Specifications
If you start a line with the number sign (#), the line is treated as a comment and does
not affect operations. You can put comments anywhere.