![Leader Evaporator Springtech EXTREME 6 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/leader-evaporator/springtech-extreme-6/springtech-extreme-6_manual_1864740028.webp)
Leader
Evaporator
Springtech
EXTREME
6
Reverse
Osmosis
System
Manual
Page:
28
Concentrate
Cycle
Valve
Settings
–
also
available
on
the
Quick
Start
Guide
1.
Position
the
valves
as
follows:
V1
–
Open
½
way
to
start
then
adjust
to
the
desired
maximum
pressure.
(Do
NOT
exceed
550
psi)
V2
–
Open
a
minimum
of
½
way
to
start
then
adjust
to
the
desired
concentration
level
of
flow.
V3
–
Horizontal
Left
V4
–
Vertical
Up
V18
–
Horizontal
Left
V19
‐
With
V3
and
V4
in
the
concentrate
setting
V19
should
have
no
flow.
Direct
V19
to
the
wash
tank
as
a
precaution
(handle
horizontal).
V6
–
The
flow
indicator
should
be
toward
the
pipe
incoming
from
the
exterior
source
selector.
Input
from
source
selector
should
be
from
the
raw
sap
(or
previously
concentrated
sap).
WD
– Horizontal,
valve
is
closed
Содержание Springtech EXTREME 6