Leader
Evaporator
Springtech
EXTREME
6
Reverse
Osmosis
System
Manual
Page:
25
Flow
Valve
Information
The
following
is
a
table
illustrating
the
type
of
valve
being
used
and
where
fluid
flows
when
the
valves
are
in
certain
positions.
NOTE:
Flow
as
stated
only
occurs
when
all
valves
are
set
for
the
proper
cycles.
VALVE
TYPE
HANDLE
POSITION
LIQUID
FROM
‐
TO
HANDLE
POSITION
LIQUID
FROM
‐
TO
V3
3
‐
Way
HANDLE
POINTS
HORIZONTAL
Membranes
to
Permeate
out
HANDLE
POINTS
VERTICAL
Membranes
to
Valve
V19
V4
3
‐
Way
HANDLE
POINTS
VERTICAL
Membranes
to
Concentrate
out
HANDLE
POINTS
HORIZONTAL
Membranes
to
Valve
V19
V6
3
‐
Way
HANDLE
POINTS
VERTICAL
External
to
Feed
Pump
HANDLE
POINTS
HORIZONTAL
Wash
Tank
to
Feed
Pump
V18
2
‐
Way
HANDLE
POINTS
HORIZONTAL
No
Flow
HANDLE
POINTS
VERTICAL
Membranes
to
Valve
V19
V19
3
‐
Way
HANDLE
POINTS
HORIZONTAL
Membranes
to
Wash
Tank
HANDLE
POINTS
VERTICAL
Membranes
to
Drain
The
following
is
a
summary
table
of
the
system
cycles
and
the
related
valve
settings
for
the
cycle
specified.
Detail
on
the
cycle
settings
is
in
the
sections
that
follow.
CYCLE
Concentrate
Desugar
Rinse
Wash
V1
Open
½
way
then
adjust
Open
½
way then
adjust
Open
Fully
Open
Fully
V2
Open
minimum
½
way
then
adjust
Open
minimum
½
way
then
adjust
Open
Fully
Open
Fully
V3
Handle
Points
Horizontal
Handle
Points
Horizontal
Handle
Points
Vertical
Handle
Points
Vertical
V4
Handle
Points
Vertical
Handle
Points
Vertical
Handle
Points
Horizontal
Handle
Points
Horizontal
V6
Handle
Points
Vertical
Handle
Points
Vertical
Handle
Points
Vertical
Handle
Points
Vertical
V18
Handle
Points
Horizontal
Handle
Points
Horizontal
Handle
Points Vertical
Handle
Points
Vertical
V19
Handle
Points
Horizontal
Handle
Points
Horizontal
Handle
Points Vertical
Handle
Points
Horizontal
Drains
Closed
Closed
Closed
Closed
NOTE:
During
the
Rinse
cycle,
if
the
machine
shuts
down
due
to
low
pressure
and
the
feed
line
has
been
bled
or
during
the
Wash
cycle
the
machine
shuts
down
due
to
low
pressure,
check
the
prefilters.
If
the
prefilters
are
dirty,
replace
and
retry
the
rinse/wash
cycle.
If
the
prefilters
appear
clean
or
are
new
and
the
problem
continues,
partially
close
valve
V18
until
an
operating
pressure
of
50
–
80
psi
is
reached
and
run
the
remainder
of
the
cycle.
During
operation
the
recirculation
pumps
continuously
recirculate
the
liquid
within
the
pressure
vessel.
Flow
between
vessels
occurs
at
the
rate
fluid
(concentrate
and
permeate)
is
withdrawn
from
the
system.
The
table
below
illustrates
the
fluid
path
for
each
cycle
through
the
control
valves,
pumps
and
pressure
vessels
Содержание Springtech EXTREME 6
Страница 24: ...Leader Evaporator Springtech EXTREME 6 Reverse Osmosis System Manual Page 24...
Страница 54: ...Leader Evaporator Springtech EXTREME 6 Reverse Osmosis System Manual Page 54 ATTACHMENT 1 ELECTRICAL SCHEMATIC...
Страница 55: ...Leader Evaporator Springtech EXTREME 6 Reverse Osmosis System Manual Page 55...