80 Troubleshooting
Linkage binding or restrictive
Repair or replace linkage as required.
Lifting motor or cylinder(s) by-passsing
hydraulic fluid
Repair or replace the defective component.
Shear pin or key broken between winch
shaft and drum
Replace the key or pin.
WINCH MOTOR LEAKING
Possible cause
Remedy
Shaft seal damaged
Replace shaft seal.
Motor worn internally
Replace motor.
CONTAINER RAISES VERY SLOWLY
Possible cause
Remedy
Winch motor by-passing
Repair or replace motor.
Rear loader hydraulic system not
providing sufficient flow rate or pressure
for container handling systems
Check and repair rear loader hydraulic system
following procedures in Service Manual.
CONTAINER WON’T LIFT
Possible cause
Remedy