96 Service & Repair
4.
Shift the packer panel lever outward to apply hydraulic
pressure to the case end of the packer
panel cylinders. Hold the lever and observe the fluid flow from the open port on the rod end of
the cylinder. The flow of hydraulic fluid should be no more than 2 fluid ounces per minute. A
flow greater than 2
ounces indicates an excessive piston seal leak. If the cylinder
does not leak
excessively, continue test.
5.
Reconnect the hydraulic lines to the end of cylinder and tighten to 110
ft- lbs. Repeat steps 3-5
for the other cylinder.
6.
Shift the packer panel lever inward to retract the packer panel cylinder (to the “interrupted-cycle”
position).
7.
Disconnect and plug the hydraulic lines which connect to the case end of a packer panel cylinder.
OPERATIONAL STATUS
Truck Running
PTO Engaged
Speed Up On
Transmission Neutral
OPERATIONAL STATUS
Truck Off
PTO Disengaged
Caution!
Loosen the hydraulic fittings slowly to release any trapped pressure. Watch for inadvertent
movement of components.
OBSERVE
FLUID
FLOW
PLUG
Содержание 2R-III
Страница 1: ...2R III MAINTENANCE MANUAL...
Страница 2: ......
Страница 3: ...2R III MAINTENANCE MANUAL...
Страница 5: ......
Страница 6: ......
Страница 20: ...10 Introduction...
Страница 42: ...32 Safety...
Страница 58: ...48 Preventive Maintenance Figure 5 1 Hydraulic tank w return filter 1 2 3 4 5 6 7 8...
Страница 66: ...56 Preventive Maintenance...
Страница 102: ...92 Troubleshooting...