Check-Out 63
Pressure should be 2350 +/- 50
PSI.
If not:
5.
If the pressure is below the appropriate setting, loosen the lock nut on the relief cartridge and turn
the adjusting screw in (rotate clockwise) to reach the correct pressure. If the pressure is above the
appropriate setting, loosen the lock nut on the relief cartridge and turn the adjusting screw out
(rotate counter-clockwise) to reach the correct pressure. After readjusting, retighten the lock nut.
Repeat steps 1 through 4.