11
© by N&W GLOBAL VENDING S.p.A.
1006 83288 - 00
WEEKLY CLEANING OF BREWER UNIT
Every time coffee is refilled, or at least once a week, any
powder residue should be removed from the external parts
of the brewer unit.
CLEANING THE CAPSULE DISPENSER
Once a month, or more frequently according to the oper-
ating conditions, clean the device proceeding as follows:
- disconnect the machine from the power supply;
- take the capsule container out, holding it by the separator
ring and slightly lifting it, paying attention to the capsules
that could fall out of the container;
- remove the capsule selection disk, making sure to collect
the capsules inside the disk;
- eliminate the coffee powder and other possible residue
using a vacuum cleaner or a brush;
- clean the selection disk surfaces and the release ring
base with a cloth.
To reinstall, do as follows:
- check that the handle bearing is outside the area of
interference with the capsule selection disk. Should it be
necessary to line up the device, this can be done manu-
ally by gently rotating the agitator drive pin;
- the selection disk must be positioned so that a capsule
shift cell lines up with a release hole. Once the disk is
positioned, slightly press to insert it in its seat;
- replace the separator ring;
- replace the capsule container;
- replace the agitator/spreader;
- load the capsules;
- close the door and make a test selection. The positioning
chamber empties and the search device reposition itself
automatically.
- Wait until the capsule search and drive device stops; the
display will indicate the message “Ready for use”.
SUSPENDING FROM USE
If for any reason the machine is switched off for a period
exceeding the use-by date of the products, the following
will be necessary:
- completely empty the containers and thoroughly wash
them with the chlorine-based detergents used to clean
the mixers.
- completely empty the water system using the special
clamps.
Fig. 13
1 - Capsule container
2 - Agitator
3 - Capsule selection disk
4 - Handle bearing
5 - Drive pin
6 - Discharge ring base
7 - Discharge hole
8 - Capsule drive cell
9 - Divider ring
10 - Weight spreader
Содержание BLUE LB 3300
Страница 1: ...USE AND INSTALLATION MANUAL UK English BLUE LB 3300 Capsules DOC NO H83288 00 EDITION 1 2006 10 ...
Страница 2: ......
Страница 4: ......
Страница 56: ...N W GLOBAL VENDING S P A Sx43700 ...
Страница 57: ...LB 3330 ...
Страница 58: ...Sx46200 ...
Страница 59: ...LB 3330 ...
Страница 60: ... by N W GLOBAL VENDING SpA NOTE ...
Страница 61: ... by N W GLOBAL VENDING SpA NOTE ...
Страница 62: ... by N W GLOBAL VENDING SpA NOTE ...
Страница 64: ......