A more powerful pump can be installed in all devices if required.
Depending on the increase in pump power, this option reduces the
cooling capacity by more than 200 W. It also results in greater
device installation height for the VC 1200 (W) and VC 2000 (W)
devices. The installation of a more powerful pump is only available
ex factory.
Outdoor installation is possible for the air-cooled VC 5000,
VC 7000 and VC 10000 devices. Equipment for outdoor installation
is only possible ex factory. The device may only be installed in out-
doors if it is protected from weather influences (provide shelter or
enclosure).
Operation outdoors for outdoor temperature below 5 °C:
n
Outdoor installation is configured, the following warning is
shown:
349 Preheat device for XX min
.
The display shows this warning after the device is switched on.
It indicates the remaining pre-heating time required before the
compressor can be started. The compressor is preheated
using its own heater. The other components (pump and heater)
are started immediately when the device is switched from
standby to operation.
n
Outdoor installation is
not
configured, the following warning is
shown:
349 Preheat device!
The display shows this warning for 10 seconds after switching
on the device. It is possible to start the device afterwards.
Increased wear or damage to the compressor may
result if the compressor is not preheated!
Sound insulation is possible for the VC 5000 (W), VC 7000 (W)
and VC 10000 (W) devices. Sound insulation is only available ex
factory.
Insulation of the cooling water hydraulic system is possible for all
water-cooled devices. This insulation is available ex factory and
can also later be installed on site by the LAUDA Constant Tem-
perature Equipment service department.
More powerful pump
Outdoor installation
Sound insulation
Insulation of the cooling water
hydraulic system
Device description
Variocool
21
Содержание VC 1200
Страница 47: ...Fig 13 Menu structure part 1 Operation Variocool 47...
Страница 48: ...Fig 14 Menu structure part 2 Menu structure for Graph Clock and Standby Operation Variocool 48...
Страница 103: ...General Variocool 103...
Страница 110: ......
Страница 111: ......