LB Pinto 400 V3
29/25
The required installation tools:
?
screwdriver
?
10 mm wrench 2 pcs
?
13 mm wrench for fixing the bracket
?
Punch-down tool for the TP cord
Please note:
Fixing of unit to a rigid surface is very important for long-term alignment.
4
On-the-table test
Warning!
Do not look either into the transmitter or the receiver optics because
at this distance even the reflected laser beam can be dangerous to your eyes.
Operating the system on much shorter distance than presumed originally can
cause saturation or even permanent damage to the receiver. Always use optical
attenuators for this kind of test.
The on-the-table test is easy to do. The units should be placed at about 2 m
distance from each other with optical windows facing one another. Put an
appropriate optical attenuator between the heads. Make all the necessary
connection as described earlier to connect your device to the heads and power
up the units. Turn ON the Outdoor Interconnection Units and check if the power
LED is ON on the head.
You should be able to align the units without any tool and get full received level
on the signal strength LED’s. Make sure that the “Saturation” indicator is OFF.
Adjust your attenuators if necessary to avoid saturation of the receivers. After
obtaining the desired received level, check the data connection between devices.
If there is a transmission problem check the status of the connecting devices
(e.g. link ON) and cables. If there’s no LINK signal, connect the network
equipments back-to-back omitting the LaserBit system to ensure that they work
properly. Should they operate well, get in contact with your supplier or call the
technical support (a Problem Report Form can be found at the end of this book).