LB Pinto 400 V3
29/18
2.2.2
Power to the Head
Warning! The wrong polarity of the cables can damage the head!
2.2.3
TP Outdoor Connecting Unit
This unit is used to connect the data cable coming from the head to the data
cables coming from the local network. You must use straight connection on your
local network side. Use the connectors to connect the proper cable. Colour codes
can be seen in the figure below:
You can measure AGC detector voltage on pin 1 and 4 of the RJ11 connector.
This is used for meuserment and installation purpose only.
Data Cables
Cable from
the head
Green-white
Green
Orange- white
Orange
This is where the nec8
VDC, Ground, -8 VDC and 30
VDC is connected to the head. Use
the power cables embedded into the
head and connect them to the 4 pin
connector.
The colour codes:
Brown-white
+30 VDC
Blue-white
-8 VDC
Green-white
Ground
Orange-white
+8 VDC