LB Pinto 400 V3
29/15
2.1.3
E1, E2, E3 FO system
E1, E2, E3 connecting basically telephone exchanges. Speeds are different
E1: 2Mbps
E2: 8Mbps
E3: 34Mbps (Modular multiplexer available)
Connect the fibre cable from the head to the outdoor box and from the outdoor
box connect it straight to the multiplexer. Please note that the polarity of the RX-
TX are the key of the connection and the installation, for more information on
the multiplexers refer to the E1, E2, E3 Multiplexers users manual!
Power from the main outlet must be connected to the outdoor-box 230VAC PCB
see: Outdoor box chapter.