manualshive.com logo in svg
background image

7

Dispenser Installation

1.  Install unit to counter.
2.  Remove the splash plate and top cover.
3.  Remove the merchandiser by removing the two (2) screws 

located on the faucet plate (from left to right) above the third 

(3rd) and sixth (6th) valve. 

4.  Remove the drip tray and cup rest. 
5.  Route appropriate tubing from the water source to the plain 

water inlet at the front of the unit and connect tubing to inlet 

using the oetiker pliers and fittings, (see Plumbing Diagram 

on the front of the unit or on page 25 for reference).

A

B

C

A. Oetiker Pliers

B. Fitting

C. Tubing

D. Syrup/Water Inlet

D

6.  Route appropriate tubing from the remote carbonator to the 

carbonated water inlet and connect tubing to inlet. 

7.  If no remote carbonator is installed, install the carbonator per 

manufacturer’s instructions.

8. 

Connect tubing to water source then flush water lines to 

check for leaks

9.  Route appropriate tubing from the syrup pump location to 

the syrup inlets in front of the unit and connect tubing to all 

inlets. 

10.  Route appropriate tubing from the CO

2

 source location to the 

CO

2

 inlet at the remote carbonator location.

11.  Route the power supply cord to a grounded electrical outlet 

of the proper voltage and amperage rating.

 

DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL 

OUTLET AT THIS TIME. 

Make sure that all water lines 

are tight and unit is dry before making any electrical 

connections

WARNING

 

NO ENCHUFE TODAVÍA LA UNIDAD A UN 

 

TOMACORRIENTE CON PUESTA A TIERRA. Antes de 

efectuar las conexiones eléctricas, asegúrese de que 

 

todas las tuberías de agua estén ajustadas y que la 

 

unidad esté seca.

ADVERTENCIA

 

À CE STADE, NE BRANCHEZ PAS L’APPAREIL À UNE 

PRISE ÉLECTRIQUE MISE À LA TERRE. Veillez à ce que 

les conduites d’eau soient étanches et que l’appareil 

soit sec avant de procéder à des raccordements

 

électriques 

AVERTISSMENT

12. 

Route drain hose from designated open type drain to fitting 

on Drip Tray and connect hose to fitting.  

 

Drain line must be insulated with a closed cell 

 

insulation. Insulation must cover the entire length of 

the drain hose, including fittings. The drain should be 

installed in such a manner that water does not collect 

 

in sags or other low points, as condensation will form.

 

Línea de drenaje debe estar aislado con un aislamiento 

de células cerradas. Aislamiento debe cubrir toda la 

longitud de la manguera de drenaje, incluyendo 

 

conexiones. El drenaje debe instalarse de modo que 

el agua no se acumula en caídas u otros puntos bajos, 

como se formará condensación.

 

La ligne de vidange doit être isolé avec un isolant à 

 

cellules fermées. L’isolation doit couvrir toute la 

 

longueur du tuyau de vidange, y compris les 

 

connexions. Le drain doit être installé de telle sorte que 

l’eau ne s’y accumule pas dans les chutes ou les autres 

points faibles, parce que la condensation se forme.

CAUTION

PRECAUCIÓN

PRUDENCE

A

A. Drain Fitting

B. Drain Line

C. Drip Tray

B

C

13.  Reattach Drip Tray/Cup Rest to unit.

 

Pouring hot water down the drain may cause the Drain 

 

Tube to collapse. Allow only luke warm or cold water to 

 

enter the Drain Tube.

 

Pouring coffee, tea, or other 

 

similar substances down the drain may cause the Drain 

 

Tube to become clogged.

 

Echar agua caliente por el drenaje puede provocar que 

 

el tubo de drenaje se colapse. Permitir que sólo agua 

 

tibia o fría para entre en el tubo de drenaje. Echando 

 

café, té u otras sustancias similares en el drenaje puede 

 

causar que el tubo de drenaje se obstruya.

 

Verser l’eau chaude dans le drain Peut provoquer le tube 

 

de drainage de l’effondrement. Seulement permettre à 

 

l’eau chaude ou froide luke pour entrer dans le tuyau de 

 

vidange. Verser le café, le thé, ou autre comme 

 

substances dans le drain Peut provoquer le tuyau de 

 

vidange à se boucher.

ATTENTION

ATTENTION

ATENCIÓN

Содержание SENSATION 4800

Страница 1: ...cease operation of the unit and contact authorized service technician Service cleaning and sanitizing should be accomplished only by trained personnel Applicable safety precautions must be observed I...

Страница 2: ...attempting any internal maintenance The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel sh...

Страница 3: ...eau connect s directement une alimentation en eau potable doivent tre calibr s install s et maintenus selon les lois f d rales provinciales et locales La conduite d alimentation en eau doit tre un tuy...

Страница 4: ...t for concealed damage If evident notify delivering carrier and file a claim against the same NOTE 6 If leg kit has been provided assemble legs by tilting unit The drain spider is located to the right...

Страница 5: ...nted on top of dispenser do not install dispenser on legs Connecting lines can be run through the back of the dispenser or extend down through a counter cutout NOTE 6 In order to facilitate proper dis...

Страница 6: ...lo para que el ice puede moverse sin obstrucci n Contacto con su proveedor de fabricaci n de hielo para informaci n sobre adecuado bin termostato ATTENTION ATENCI N Failure to use an ice bin thermosta...

Страница 7: ...de proc der des raccordements lectriques AVERTISSMENT 12 Route drain hose from designated open type drain to fitting on Drip Tray and connect hose to fitting Drain line must be insulated with a closed...

Страница 8: ...ting D Oetiker Pliers D A Tee Fitting B Line to Syrup Pump C Fitting D Line to CO2 Supply A B B C D A Syrup Pump Inlet B Fitting C BIB Connector D Oetiker Pliers A B C D Installing CO2 Supply 1 Connec...

Страница 9: ...dispensador debe tener un circuito el ctrico independiente No use cables de extensi n No conecte varios dispositivos el ctricos al mismo tomacorriente F ADVERTENCIA La distributrice doit tre mise la...

Страница 10: ...t NOTE A B A Water ON B Syrup Closed 3 Using a Lancer ratio cup verify water flow rate 5 oz in 4 sec Use a screwdriver to adjust if needed 4 Remove nozzle by twisting counter clockwise and pulling dow...

Страница 11: ...140 F 60 C Puede da ar la m quina expendedora NO vierta soluci n desinfectante en ning n tablero de circuitos Aseg rese de que toda la soluci n desinfectante sea removida del sistema Utilisez des gan...

Страница 12: ...all removable parts Ensure agitator clip is locked 14 Fill Unit with ice and replace Top Cover 15 Reconnect Dispenser to power source Refer to the Automatic Agitation Warning on page 3 NOTE D fense d...

Страница 13: ...t Residual sanitizing solution left in the system creates a health hazard Despu s de la esterilizaci n enjuague con el producto final hasta que eliminar el sabor que queda No enjuague con agua fresca...

Страница 14: ...ot check to see if the solenoid leads are connected to the PC board or damaged check continuity of solenoid Replace if defective D9 This light is on when the motor is activated When the chute is depre...

Страница 15: ...CONDS SWITCH AUTO AGITATE OFF TIME 3 4 OFF OFF NO AUTO AGITATION OFF ON 20 MINUTES ON OFF 40 MINUTES ON ON 60 MINUTES To prevent possible harm to the environment from improper disposal recycle the uni...

Страница 16: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com Wiring Diagram 115 Volt...

Отзывы: