The pump deck has a 3 minute timeout feature. If the

 

timeout occurs, turn the deck OFF then ON by flipping

 

the switch on the control box.

NOTE

 

To check for CO

2

 leaks, close the valve on the CO

2

 

 

cylinder and observe if the pressure to the system 

 

drops with the  cylinder valve closed for five minutes. 

 

Open the cylinder valve after check.

NOTE

13.  Activate each valve to purge air from the syrup lines. 

Adjust Water Flow Rate & Syrup/Water Ratio

1. 

Remove valve cover from first valve.

2. 

Close syrup shut-off at mounting block for first valve.  

 

Ensure there is ice on the cold plate and the lines are 

cold before attempting to set the flow rates on the 

valves. The drink temperature should be no higher than 

40°F (4.4°C) when flow rates are set. 

NOTE

A

B

A. Water ON     

B. Syrup Closed

3. 

Using a Lancer ratio cup verify water flow rate (5 oz. in 4 

sec.). Use a screwdriver to adjust if needed.

4.  Remove nozzle by twisting counter clockwise and pulling 

down, then remove diffuser by pulling down.

A

B

Increase

Decrease

C

E

A. Flow Control, Water

B. Flow Control, Syrup

C. Nozzle (Diffuser inside)

D. Retainer Clip

E. Soda Lever

D

5.  Install Lancer (yellow) syrup seperator 

(PN 54-0031)

 in place 

of nozzle.

6. 

Re-open syrup shut-off at mounting block.

7. 

Activate valve to purge syrup until steady flow is achieved.

8.  Using a Lancer brix cup, activate the valve and capture a 

sample. Verify that the syrup level is even with the water 

level. Use a screwdriver to adjust if needed. 

9.  Remove syrup seperator and reinstall nozzle. Replace valve 

cover.

10.  Repeat steps 1-8 for each valve. 
11.  Re-install merchandiser, splash plate, and top cover. 

A

B

C

A. Nozzle

B. Diffuser

C. Soda Lever

A

B

A. Syrup Seperator

B. Soda Lever

Содержание SENSATION 4800

Страница 1: ...cease operation of the unit and contact authorized service technician Service cleaning and sanitizing should be accomplished only by trained personnel Applicable safety precautions must be observed I...

Страница 2: ...attempting any internal maintenance The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel sh...

Страница 3: ...eau connect s directement une alimentation en eau potable doivent tre calibr s install s et maintenus selon les lois f d rales provinciales et locales La conduite d alimentation en eau doit tre un tuy...

Страница 4: ...t for concealed damage If evident notify delivering carrier and file a claim against the same NOTE 6 If leg kit has been provided assemble legs by tilting unit The drain spider is located to the right...

Страница 5: ...nted on top of dispenser do not install dispenser on legs Connecting lines can be run through the back of the dispenser or extend down through a counter cutout NOTE 6 In order to facilitate proper dis...

Страница 6: ...lo para que el ice puede moverse sin obstrucci n Contacto con su proveedor de fabricaci n de hielo para informaci n sobre adecuado bin termostato ATTENTION ATENCI N Failure to use an ice bin thermosta...

Страница 7: ...de proc der des raccordements lectriques AVERTISSMENT 12 Route drain hose from designated open type drain to fitting on Drip Tray and connect hose to fitting Drain line must be insulated with a closed...

Страница 8: ...ting D Oetiker Pliers D A Tee Fitting B Line to Syrup Pump C Fitting D Line to CO2 Supply A B B C D A Syrup Pump Inlet B Fitting C BIB Connector D Oetiker Pliers A B C D Installing CO2 Supply 1 Connec...

Страница 9: ...dispensador debe tener un circuito el ctrico independiente No use cables de extensi n No conecte varios dispositivos el ctricos al mismo tomacorriente F ADVERTENCIA La distributrice doit tre mise la...

Страница 10: ...t NOTE A B A Water ON B Syrup Closed 3 Using a Lancer ratio cup verify water flow rate 5 oz in 4 sec Use a screwdriver to adjust if needed 4 Remove nozzle by twisting counter clockwise and pulling dow...

Страница 11: ...140 F 60 C Puede da ar la m quina expendedora NO vierta soluci n desinfectante en ning n tablero de circuitos Aseg rese de que toda la soluci n desinfectante sea removida del sistema Utilisez des gan...

Страница 12: ...all removable parts Ensure agitator clip is locked 14 Fill Unit with ice and replace Top Cover 15 Reconnect Dispenser to power source Refer to the Automatic Agitation Warning on page 3 NOTE D fense d...

Страница 13: ...t Residual sanitizing solution left in the system creates a health hazard Despu s de la esterilizaci n enjuague con el producto final hasta que eliminar el sabor que queda No enjuague con agua fresca...

Страница 14: ...ot check to see if the solenoid leads are connected to the PC board or damaged check continuity of solenoid Replace if defective D9 This light is on when the motor is activated When the chute is depre...

Страница 15: ...CONDS SWITCH AUTO AGITATE OFF TIME 3 4 OFF OFF NO AUTO AGITATION OFF ON 20 MINUTES ON OFF 40 MINUTES ON ON 60 MINUTES To prevent possible harm to the environment from improper disposal recycle the uni...

Страница 16: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com Wiring Diagram 115 Volt...

Отзывы: