L. Remount agitator motor to agitator deck.
M. Connect wiring harness to agitator deck. If control failed and caused unit to freeze up and the
unit is still frozen at time of repair, the compressor may start and operate for a short period of
time, while ice is built around control bulb, causing control to shut off compressor. At time of
repair, if unit is frozen up to the extent that the water coils are frozen and product cannot be
dispensed, it will be necessary to partially defrost ice bank. If defrost is necessary, pour warm
water into water bath.
NOTE
Instead of defrosting ice bank, the unit power cord can be left unplugged from electrical outlet
for about six (6) to eight (8) hours and then plugged back into electrical outlet by operator.
N. Replace lid.
6.16 AGITATOR MOTOR
WARNING
DISCONNECT THE POWER CORD FROM THE ELECTRICAL OUTLET.
A. Remove lid over agitator deck.
B. Unplug wiring harness from agitator deck.
C. Remove four (4) screws holding agitator motor bracket to agitator deck.
D. Disconnect agitator motor from wiring harness and remove.
E. Remove propeller from shaft if damaged. Inspect propeller to be sure no blades are broken.
F. Replace agitator motor and propeller by reversing above procedure.
6.17 AGITATOR DECK
WARNING
DISCONNECT THE POWER CORD FROM THE ELECTRICAL OUTLET.
A. Remove lid over agitator deck.
B. Unplug wiring harness from agitator deck.
C. Remove two (2) nuts holding agitator deck to tank assembly.
D. If unit has an ice bank, remove seal and pour about 12 ounces (354.8 ml) of warm water into
retainer to defrost and detach from ice bank.
E. Lift agitator deck out of unit.
F. To reassemble, reverse above procedure.
NOTE
The retainer is attached to the agitator deck with a sleeve which is pressed onto the retainer.
The sleeve must be tight against bottom of agitator deck so that the retainer is held firmly to the
agitator deck. If the retainer is loose, the ice bank size will vary and may cause a freeze-up of
the unit.
6.18 WATER COIL CAGE ASSEMBLY
WARNING
DISCONNECT THE POWER CORD FROM THE ELECTRICAL OUTLET.
A. Close inlet water shut off valve.
B. Remove agitator deck (refer to Section 6.17).
C. Remove water from ice bank compartment.
D. Loosen tubing nuts on water coil.
E. Remove four (4) nuts holding cage assembly to bottom of tank.
F. Remove cage assembly from tank.
G. Remove defective water coil from cage assembly.
H. Reassemble cage assembly in tank by reversing procedure. Tighten water coil tubing nuts 1/4
turn after finger tight.
I.
Open inlet water shut off valve and check for leaks.
J. Refill ice bank compartment to overflow port.
K. Replace agitator deck and lid.
13
Содержание CENTURION II 85-0056
Страница 28: ...11 ILLUSTRATIONS PARTS LISTINGS AND WIRING DIAGRAMS 11 1 CENTURION II FINAL ASSEMBLY 24 ...
Страница 30: ...26 11 2 CENTURION II PUMP REGULATOR ASSEMBLY ...
Страница 32: ...11 3 CENTURION II WATER CONCENTRATE COMPONENT ASSEMBLY 28 ...
Страница 34: ...30 11 4 CENTURION II REFRIGERATION ASSEMBLY ...
Страница 38: ...11 7 CENTURION II WIRING DIAGRAM 34 ...