Built-in Single Split Cavity Oven
LAM3676
Instructions and Installation
Before installation
The product must only be installed
by suitably qualified persons.
The product must be installed
in accordance with all local
regulations.
Prior to installation, visually
check the product for any
damage / defects. Do not
install if any issues are found.
Damaged products may cause
risks to your own safety.
• The appliance is intended for
installation in Howdens kitchen
cabinets.
• Surfaces, synthetic laminates
and adhesives used must be
heat resistant.
• Kitchen cabinets must be set
level and fixed.
• If there is a drawer beneath the
oven, a shelf must be installed
between oven and drawer.
• The following installation
drawings are representational
and may not match exactly
with your appliance.
10. Installation
** The oven may need to be
positioned lower in the cabinet
to fit with some hobs
Built under installation
Tower Installation
Note: Remove carcass rear panel
to assist with oven ventilation.
* A minimum of 150mm
2
ventilation
gap is required as illustrated
(35mm x 500mm cut-out)
Electrical connections
•
IMPORTANT:
Ensure that the electricity supply is switched off before
connecting. Your oven is intended for permanent installation.
• Your appliance must be connected to fixed wiring via the use of a
double pole switched fused spur outlet with at least 3mm contact
separation. The isolation switch must be accessible after installation
(see technical data for fuse rating). We recommend the use of an
RCD device as additional protection.
• The product must only be installed by a suitably qualified person.
The product must be installed in accordance with all local regulations.
• The terminology DOUBLE POLE- / + means that both the live and
neutral supplies are switched and disconnected at the same time.
• The terminations labelled SUPPLY are connections for the internal
house wiring and the terminations labelled LOAD are for connection
to the appliance.
•
IMPORTANT:
The wires in
the mains lead are coloured in
accordance with the following;
BLUE
= Neutral
BROWN
= Live
GREEN
/
YELLOW
= Earth
• As the colours of the wires in
the mains lead of this appliance
may not correspond with the
coloured markings identifying
the terminals in your spur box,
proceed as follows;
• The wire which is coloured
blue must be connected to
the terminal which is marked
with the letter ‘N’ or coloured
‘BLACK’. The wire which
coloured brown must be
connected to the terminal
which is marked with the letter
‘L’ or coloured RED. The green
and yellow earth ‘E’ should
be connected to the terminal
marked with the following
symbol .
BROWN
(Live)
BLUE
(Neutral)
GREEN
/
YELLOW
(Earth)