37
GENERAL INSTRUCTIONS
●
This booklet constitutes an integral and essential part of the product.
Read carefully the instructions contained in this booklet as they provide important directions regarding the
safety of installation, use and maintenance. Preserve this booklet with care for any further consultation.
The installation of the boiler must be carried out in compliance with current regulations, according to the
instructions of the manufacturer and by qualified personnel. An incorrect installation can cause injury or
damage to persons, animals and objects, for which the manufacturer cannot be held responsible.
●
After removing the packaging materials, check the content integrity. In case of doubt, do not use the unit
and contact the supplier. The packaging material (wooden crates, nails, clips, plastic bags, foam, etc.)
must not be left within reach of children as they are potential sources of danger.
●
This boiler is designed to heat water to a temperature below boiling point (atmospheric pressure). It must
be connected to a heating system compatible with its performance and output.
●
This appliance should only be used for the purposes for which it has been expressly designed. Any other
use is to be considered improper and therefore dangerous. The manufacturer cannot be considered
responsible for any damages caused by improper or unreasonable use.
ALL INSTALLATION, MAINTENANCE AND GAS CONVERSION OPERATIONS MUST BE CARRIED OUT BY
AUTHORISED QUALIFIED TECHNICIANS.
TO ENSURE THAT BOILER IS INSTALLED CORRECTLY AND THAT IT FUNCTIONS PROPERLY, WE RECOMMEND
THAT ONLY LAMBORGHINI ACCESSORIES AND SPARE PARTS BE USED.
ON NOTICING THE SMELL OF GAS DO NOT TOUCH ANY ELECTRIC SWITCHES. OPEN DOORS AND
WINDOWS. SHUT OFF THE GAS COCKS.
INSTALL THE BOILER ON WALLS WHICH ARE AS WIDE OR WIDER THAN THE BOILER ITSELF.
92
ESQUEMA DE MONTAJE (VÉASE EL CIRCUITO HIDRÁULICO 3) CON INSTALACIÓN EN VARIAS ZONAS
ATENCIÓN!: la carga de los circuladores auxiliares no tiene que superar los 5A.
230 V
50 Hz
monofásica
DESCRIPCIÓN
C
Conector Wieland
CiA1-2
Circulador auxiliar
CiB
Circulador acumulador
CiR
Circulador instalación
E.A.
Electrodo de encendido
E.R.
Electrodo de detección
FA
Filtro antiparasitario
FLT1
Conexión Flat para botonera
digital
FLT2
Conexión Flat para kit
acumulador
IG
Interruptor general
KCB
Kit conexión acumulador
M1
Regleta de bornes 8 polos
M2
Regleta de bornes 7 polos
M3
Regleta de bornes 4 polos
M4
Regleta de bornes 5 polos
M5
Preparación para kit
acumulador
M6
Preparación para conexión
con la tarjeta de la caldera
PA
Presostato aire
Pma
Presostato falta de agua
PSG
Presostato de seguridad gas
R1-2
Relé (si lo hubiera)
SE
Sonda exterior (si lo hubiera)
SR
Sonda retorno
SM
Sonda ida
TA1-2
Termostato ambiente
(si lo hubiera)
TB
Termostato acumulador
TRA
Transformador
VG
Válvula gas 1-2
VN
Ventilador
X2
Conector amp. 13 vías
X3
Conector amp. 6 vías
X4-X5
Conector amp. 2 vías