39
To be carried out by qualified personnel.
The system must be installed in an area free from corrosive vapours and must comply with the legal standards
in force regarding evacuation of combustion by-products. It is especially recommended that standards concerning
safety, construction and flue positioning be strictly observed.
SYSTEM START-UP
●
Open windows and doors and do not light any naked flames.
●
Bleed the air
●
Check that there are no gas leaks (use soapy water or an equivalent product).
Before installing the boiler it is important to remove any impurities from the water supply pipes; use air or
inert gas.
Make sure that the boiler is suitable for the type of gas available to the user.
INSTALLATION
90
CONEXIONES HIDRÁULICAS
SÓLO CALEFACCIÓN
A TEMPERATURA
VARIABLE 30
°
C
90
°
C
CALEFACCIÓN A TEMPERA-
TURA VARIABLE 30
°
C/90
°
C
Y ACUMULADOR DE ALTA
TEMPERATURA 60
°
C/90
°
C
ACUM CALEFACCIÓN CON
RADIADORES (ALTA TEMPERATURA) O
CALEFACCIÓN DE SUELO (BAJA TEMPERA-
TURA) CON VÁLVULA MEZCLADORA
R
Radiador
RR
Retorno calefacción
V
Válvula sin retorno
VM
Válvula mezcladora
B
Acumulador
CE
Colector ecualizador
CiA
Circulador auxiliar
CiB
Circulador acumulador
CiR
Circulador de calefacción
IP
Instalación de suelo
MR
Ida calefacción
RB
Retorno acumulador
1
2
3
INSTALACIÓN DEL CIRCULADOR AUXILIAR (ACUMULADOR)
Si fuera necesario instalar el circulador auxiliar
(acumulador), quite el tronco
A
e introduzca el
circulador.
A