38
Outlet water hardness
Information
This option is displayed only if
SH
(regeneration mode) is set to 1 or to 2.
Obligatory
Make sure the mixing device is correctly configured to match the programmed
value.
Obligatory
Use the same unit as the one used for the inlet hardness.
Set the outlet water hardness in °f (French degrees), °d (German
degrees) or mg/L of CaCO
3
.
A
Use
and
to set the hardness.
B
Press
to confirm and go to the next parameter.
Resin exchange capacity
Information
This option is displayed only if
SH
(regeneration mode) is set to 1 or to 2.
Obligatory
Use the same unit as the one used for the hardness.
Obligatory
If the mixing device is installed downstream of the meter, set this parameter to 0.
Information
The resin exchange capacity can be set from 1 to 10 in °f·m
3
/L, °d·m
3
/L or g of
CaCO
3
/L
Resin
.
Set the resin exchange capacity.
A
Use
and
to set the exchange capacity.
B
Press
to confirm and go to the next parameter.
Salt dosage
Information
The salt dosage can be set from 80 to 200 g/L.
Set the quantity of salt in grams per litre of resin to be
used for each regeneration.
A
Use
and
to set the dosage.
B
Press
to confirm and go to the next parameter.