58
ECO Green start-up
After connecting the device to the hydraulic circuit and having checked that all the
hydraulic seal components have been assembled correctly, proceed as follows:
1
Slowly open the softener water flow; wait until clean water comes out of the drain.
2
Perform an additional regeneration (see booklets provided)
3
Check the seal of the installation
4
Check the electrics/hydraulics
5
Open the softened water flow to the system making sure to check the residual
hardness (installing or creating a mixing assembly) according to current standards.
6
It is advisable to connect the valve drain with a flexible pipe dia. 20 mm.
KEY
1
Dissolver pipe
2
Overflow
3
Coupling for draw pipe
4
Valve rod
5
Safety valve
6
Salt container
Note:
Plug the unused overflow
using a suitable plug
(See Fig. 5.pos.2)
MAXIMUM
SALT LEVEL